EXPLODED VIEW: CONBOX C2 CPL

DRAWING #: 0H7326

APPLICABLE TO:

GROUP A

ITEM

PART#

QTY.

DESCRIPTION

 

 

 

 

 

 

 

UL CIRCUIT BREAKER (225AF)

A

0G5250

1

CB 175A 2 POLE 240V 225AF

B

0H7356

1

COVER CB C2 CPL

C

0F4186AGS0R

1

COVER CB DISH 2P G 225AF

D

0F8432A

1

INSULATOR CB 2P 225AF

E

0H7311

1

STANDOFF CB BOX CONBOX

F

045771

2

NUT HEX M8-1.25 G8 CLEAR ZINC

G

036261

4

RIVET POP .125 X .275 SS

H

0C2454

12

SCREW HWHT M6-1 X 16 N WA Z/JS

J

053640

2

SCREW RHM #8-32 X 3-1/4

K

038150

2

WASHER FLAT #8 ZINC

L

022264

2

WASHER LOCK #8-M4

M

022471

2

NUT HEX #8-32 STEEL

N

049897

4

SCREW SHC M8-1.25 X 20 G8

P

022129

6

WASHER LOCK M8-5/16

R

022145

4

WASHER FLAT 5/16-M8 ZINC

S

058306

2

SCREW SHC M8-1.25 X 25 C12.9

T

0F8843

2

BUS BAR 200A LUG ADAPTOR

U

0F8451

2

LUG SLDLSS 300 MCM-6 AL/CU

 

 

 

UL CIRCUIT BREAKER (400AF)

A

0F4153

1

CB 0250A 3P 480V G 400AF

B

0H6735

1

COVER CB 400AF C2 CONBOX

C

0A7822

3

LUG SLDLSS 600/250-1/0X1/4-28

D

0H6734

1

STANDOFF CB MOUNT CONBOX

E

042419

4

SCREW RHM 10-32 X 4

F

022097

6

WASHER LOCK M6-1/4

G

052647

6

SCREW SHC M10-1.5 X 25 C12.9

H

0C2454

12

SCREW HWHT M6-1 X 16 N WA Z/JS

J

046526

6

WASHER LOCK M10

K

023897

4

WASHER FLAT #10 ZINC

L

022152

4

WASHER LOCK #10

M

022158

4

NUT HEX #10-32 STEEL

N

023334

6

SCREW HHC 1/4-28 X 1/2 G5

P

022473

6

WASHER FLAT 1/4-M6 ZINC

(1)ITEMS INCLUDED WITH HARNESS P/N 0H6692.

(2)ITEMS INCLUDED WITH NEUTRAL BLOCK P/N 0D5464B.

(3)ITEMS INCLUDED WITH 4.2L MODELS ONLY.

(4)SEE “C2 DPE BREAKER SELECTION” TABLE.

(5)QTY. REQ. FOR 2 POLE BREAKER / QTY. REQ. FOR 3 POLE BREAKER.

(6)SHEET METAL PARTS LISTED IN THE BOM TABLE ARE REPRESENTING GENERIC PARTS (NO COLOR).

MANUFACTURING: FOR CORRECT MATERIAL AND COLOR REFER TO AS400 BOM.

CUSTOMER: FOR CORRECT MATERIAL AND COLOR OF REPLACEMENT PARTS REFER TO “REPLACEMENT SHEET METAL PARTS ORDERING GUIDE-0H7169 INCLUDED IN THE MANUAL OR AVAILABLE ON THE GENERAC WEBSITE.

PAGE 3 OF 8

REVISION: -A-

DATE: 3/31/10

Page 34
Image 34
Generac QT04524ANSX owner manual UL Circuit Breaker 225AF