Section 2 – Operation

Recreational Vehicle Generator

‹2.9.3 FIELD BOOST

The Controller Circuit Board houses a field boost diode and resistor that are not part of the automatic choke circuit. These two components are part of a “field boost” circuit (Figure 2.3). During engine cranking only, a positive DC (battery) voltage is delivered through the diode, resistor, brushes and slip rings, to the generator rotor. Application of this voltage to the rotor “flashes the field” whenever it is started. Flashing of the field each time the generator starts makes sure that a sufficiently strong magnetic field is available to produce “pickup” voltage in the stator windings.

Figure 2.3 – Field Boost Circuit

The voltage regulator also incorporates a “voltage surge protection circuit.” This circuit prevents trou- blesome surges in the generator AC output voltage. Voltage surge is a common cause of damage to elec- tronic equipment.

2.10 ADDITIONAL INFORMATION

‹2.10.1 25-HOUR BREAK-IN PERIOD

The first 25 hours of operation is the break-in period for the generator. Properly breaking in the genera- tor is essential to minimize fuel consumption and provide maximum engine performance. During this

25-hour break-in period, follow this procedure:

Run the unit at varying electrical loads to help seat the engine piston rings properly.

Check the engine oil level frequently. Add oil if needed. It is normal for the generator engine to consume more oil than is normal until the piston rings have properly seated.

For the 75-hour operation following the break-in period, avoid light electrical loads. Load the gen- erator at 50 percent (or more) of its rated watt- age capacity. Repeated light loads during these 75 hours can cause improper seating of engine piston rings, resulting in blowby and high oil consump- tion.

After operating the unit for 25 hours, complete the tasks recommended under Section 2.10.2.

‹2.9.4 OVERVOLTAGE PROTECTION

A solid-state voltage regulator (Figure 2.4) controls the generator’s AC output voltage. This regulator sup- plies an excitation current to the rotor. By regulating the rotor’s excitation current, the strength of its mag- netic field is regulated and, in turn, the voltage deliv- ered to connected electrical loads is controlled. When the AC frequency is 60 Hertz, voltage is regulated at 120 volts (voltage-to-frequency ratio is 2-to-1).

Figure 2.4 – Solid State Voltage Regulator

‹2.10.2 25-HOUR CHECK-UP

After the 25-hour break-in period, contact an Authorized Service Dealer for the following main- tenance. The vehicle owner is responsible for any charges:

Change the engine crankcase oil and oil filter.

Check the oil level.

Inspect the cooling and ventilation openings.

Check the engine carburetor adjustments.

Check the engine ignition system.

Inspect the entire electrical system.

Inspect the engine exhaust system.

‹2.10.3 ATTENTION REQUIRED AFTER SUBMERSION

If the recreational vehicle generator has been sub- merged in water, it MUST NOT be started and oper- ated. Following any submersion in water, have an Authorized Service Dealer thoroughly clean and dry the generator.

10

Page 12
Image 12
Generac Power Systems 004700-00 owner manual Additional Information, ‹ 2.9.3 Field Boost, ‹ 2.10.1 25-HOUR BREAK-IN Period

004700-00 specifications

Generac Power Systems is a recognized leader in the field of backup power generation, and one of its standout products is the Generac 004700-00. This reliable and high-performance generator has garnered attention for its robust features and advanced technological capabilities, making it an appealing choice for homeowners and businesses alike.

One of the key features of the Generac 004700-00 is its ability to deliver a reliable source of power during outages. With a powerful engine, this generator is designed to handle substantial loads, including sensitive electronics, heating systems, and appliances without compromising performance. The generator achieves this with a recommended horsepower rating that ensures a steady output even under heavy demand.

Incorporating Generac’s advanced Synch Power technology, the 004700-00 enables users to operate multiple devices simultaneously without any disruption. This feature ensures that the power provided is stable and consistent, minimizing the risk of damage to electronic devices during surges or fluctuations. Furthermore, the generator is engineered with a user-friendly control panel, making it easy to monitor performance metrics and adjust settings as necessary.

A standout characteristic of the 004700-00 is its quiet operation. Unlike many traditional generators, this unit utilizes noise-reducing technologies, ensuring that it operates at a lower decibel level. This feature is particularly beneficial for residential areas, where noise restrictions may be a concern.

The Generac 004700-00 also excels in fuel efficiency, allowing it to run longer on less fuel. This is achieved through its advanced engine design and efficient fuel consumption rate, which not only saves on operating costs but also reduces the environmental impact. Additionally, the generator is compatible with various fuel types, enhancing its versatility and convenience for users.

Ease of maintenance is another consideration with the 004700-00, as it is equipped with a maintenance alert system that notifies users when service is required. This proactive approach to care ensures that the generator remains in optimal working condition, prolonging its lifespan and reliability.

In summary, the Generac Power Systems 004700-00 stands out with its powerful performance, advanced technology, quiet operation, fuel efficiency, and user-friendly features. Whether for residential or commercial use, this generator provides a dependable solution for anyone in need of backup power when it matters most.