Generac Power Systems 005219-0 Standby Generator Sets Specifications, ‹ Generator, ‹ Engine

Models: 005219-0

1 60
Download 60 pages 54.16 Kb
Page 10
Image 10
Standby Generator Sets

Standby Generator Sets

Specifications

SPECIFICATIONS

‹ GENERATOR

Type

Synchronous

Rotor Insulation

Class F or H

Stator Insulation

Class H

Total Harmonic Distortion

< 3.5%

Telephone Interference Factor (TIF)

< 50

Alternator Output Leads 3-phase

4-wire

Bearings

Sealed Ball

Coupling

Flexible Disc

Load Capacity (Standby Rating)

30kW*

*NOTE: Generator rating and performance in accordance with ISO8528-5, BS5514, SAE J1349, ISO3046 and DIN 6271 Standards. KW rating is based on LPG fuel and may derate with natural gas.

Excitation System

 

Direct

Generator Output Voltage/kW - 60 Hz

kW

Amp

CB Size

120/240V, 1-phase, 1.0 pf

30

125

150

120/208V, 3-phase, 0.8 pf

30

104

125

277/480V, 3-phase, 0.8 pf

30

45

50

Generator Locked Rotor KVA Available @ Voltage Dip of 35%

 

Single-phase or 208 3-phase

 

60

KVA

480V, 3-phase

 

70

KVA

‹ ENGINE

Make

Generac

Model

V-type

Cylinders and Arrangement

6

Displacement

3.0 Liter

Bore

3.55 in.

Stroke

3.1 in.

Compression Ratio

9.3-to-1

Air Intake System

Naturally Aspirated

Valve Seats

Hardened

Lifter Type

Hydraulic

Engine Parameters

 

Rated Synchronous RPM

60 Hz, 1800

HP at rated kW

60 Hz, 48

Exhaust System

 

Exhaust Flow at Rated Output 60 Hz

200 cfm

Exhaust Temperature at Rated Output

890° F

Engine Lubrication System

 

Type of Oil Pump

Gear

Oil Filter

Full Flow, Cartridge

Crankcase Oil Capacity

4 U.S. qts.

‹ COOLING SYSTEM

Type

Closed

Water Pump

Belt Driven

Fan Speed

2150

Fan Diameter

18 inches

Fan Mode

Pusher

Air Flow (inlet air including alternator and

 

combustion air)

2460 ft3/min.

Coolant Capacity

(2.5 U.S. gal.)

Heat Rejection to Coolant

115,000 Btu/h

Maximum Operating Air Temp. on Radiator

60° C (150° F)

Maximum Ambient Temperature

50° C (140° F)

‹FUEL SYSTEM

Type of Fuel

.........................................

Natural Gas, Propane Vapor

Carburetor

 

 

Down Draft

Secondary Fuel Regulator

 

Standard

Fuel Shut-off Solenoid

 

Standard

Operating Fuel Pressure

5 in. - 14 in. Water Column

Fuel Consumption - ft3/hr (Natural Gas/LPV)

Exercise

25%

50%

75%

100%

Cycle

Load

Load

Load

Load

70/28.3

111/45

214/86.1

298/120

412/166

‹ELECTRICAL SYSTEM

Battery Charge Alternator

............................................12V, 30 Amp

Static Battery Charger

2 Amp

Recommended Battery

24F 525CCA

System Voltage

12 Volts

Voltage Regulator

 

Type

Electronic

Sensing

Single-phase

Regulation

± 1%

Features

V/F Adjustable, Adjustable

 

Voltage and Gain LED Indicators

Power Adjustment for Ambient Conditions

Combustion Air Requirements (Natural Gas)

Flow at rated power, 60 Hz

................................................... 92 cfm

Governor

 

Type

Electronic

Frequency Regulation

Isochronous

Steady State Regulation

± 1/2%

Adjustments:

 

Speed

Selectable

Temperature Deration

 

3% for every 10° C above °C

25

1.65% for every 10° above °F

77

Altitude Deration

 

1% for every 100 m above m

183

3% for every 1000 ft. above ft

600

Controller

R-100

6-1

11/05 C .Rev GenSpec002

Page 10
Image 10
Generac Power Systems 005219-0 Standby Generator Sets Specifications, ‹ Generator, ‹ Engine, ‹ Cooling System, 100%