Generac Power Systems 009600-5, 009734-5 1.6SPECIFICATIONS, Fuel Consumption gph/lbs.ph, 1.6.3

Models: 009600-5, 009734-5

1 60
Download 60 pages 59.34 Kb
Page 8
Image 8
Figure 1.1 – Connection for 120 Volts Only

Section 1 – General Information

PRIMEPACT 66G and 66LP Recreational Vehicle Generators

Figure 1.1 – Connection for 120 Volts Only

Figure 1.2 - Connection for 120/240 Volts

Fuel Consumption (gph/lbs.ph)

 

Model

No Load

1/2 Load

Full Load

 

 

PrimePact 66G

0.33

0.59

0.99

 

 

PrimePact 66LP

0.47/2.01

0.85/3.62

1.66/7.05

 

NOTE

Some installations using a “shared” fuel tank may have a generator fuel pickup tube that is shorter than the vehicle engine’s pickup tube. Such an arrangement causes the generator engine to “run out of gas” while adequate fuel for the vehicle remains in the tank.

To reduce lead and carbon deposits use high quality UNLEADED gasoline with the generator. Leaded REGULAR grade gasoline is an acceptable substitute.

NOTE:

Using unleaded gasoline contributes to longer engine valve life by reducing lead and carbon deposits.

CB1

T1

RED

T2

Generac does not recommend using any gasoline containing alcohol (such as “gasohol”). If you use any gasoline containing alcohol, it must not contain more than 10 percent ethanol,

WHITE

CB2T3

BLACK

STATOR WINDINGS GROUNDED NEUTRAL

1.6SPECIFICATIONS

1.6.1 FUEL REQUIREMENTS

This generator is equipped with a gasoline fuel system as standard equipment. Specific installations may pro- vide either a separate fuel tank for the generator, or the generator may “share” the vehicle engine’s fuel tank.

and it must be removed from the generator during storage. Do NOT use any gasoline containing methanol. If you use gasoline with alcohol, inspect more frequently for fuel leaks and other abnormalities.

1.6.2 ENGINE OIL REQUIREMENTS

Use only high quality detergent oil classified “For Service SF” and with an oil viscosity rating of SAE 10W-30 oil. Do not pour in any additives to the rec- ommended oil. Engine crankcase capacity is 1.4 liters. See Section 3.2 on page 11 for oil level check and filing procedures.

 

 

1.6.3

GENERATOR SPECIFICATIONS

 

 

 

SERIES

 

PRIMEPACT 66G

 

PRIMEPACT 66LP

 

 

Rotor RPM

 

3600

 

3600

 

 

Rotor Poles

 

2

 

2

 

 

Engine RPM

 

2700

 

2700

 

 

Rated Max. Continuous AC Output*

 

6600 watts (6.6 kW)

 

6200 watts (6.2 kW)

 

 

Voltage*

 

120

 

120

 

 

Rated Max. Continuous Current*

 

55.0 AC amps‡

 

51.7 AC amps Ñ

 

 

Phase

 

1

 

1

 

 

Frequency

 

60 Hertz

 

60 Hertz

 

 

Battery Charging Current (Max.)

 

2 amps (trickle charge)

 

2 amps (trickle charge)

 

 

Weight

 

213 pounds

 

216 pounds

 

 

Length

 

25 inches

 

25.75 inches

 

 

Width

 

18.5 inches

 

18.5 inches

 

 

Height

 

15.75 inches

 

15.75 inches

 

 

 

 

 

 

 

 

*All units are reconnectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output

‡ Rated maximum continuous current at 240 volts is 27.5 amps. Ñ Rated maximum continuous current at 240 volts is 25.8 amps.

6 Generac® Power Systems, Inc.