Second Edition • Fourth Printing | Operator’s Manual |
|
|
|
|
Test Auxiliary Platform Lowering
20 Raise the platform slightly.
Result: The inner frame wheels should lift off the ground.
21Disconnect the power source from the machine.
22Turn the key switch to ground control (if equipped).
23Push in the auxiliary platform lowering button at the ground controls.
Result: The platform should lower.
24Connect the power source to the machine.
25Turn the key switch to platform control (if equipped).
26Raise the platform slightly.
27Disconnect the power source from the machine.
28At the platform controls, push in the control activate button and rotate the up/down switch in the down direction.
Result: The platform should lower.
29 Connect the power source to the machine.
Test Manual Lowering
30Twist to release the red Emergency Stop button at the platform controls. Confirm that the interlock display lights and the power light are on.
31Push in the control activate button and rotate the up/down switch to the UP position to raise the platform approximately 6 inches / 15 cm.
32Activate the manual lowering valve located at the bottom of the
hydraulic cylinder.
Result: The platform should lower.
FUNCTION TESTS
Test Platform Raise and Lower
33Push in the control activate button and rotate the up/down switch to the UP position.
ANSI & CSA | CE |
a | b | a | b |
acontrol activate button
bup/down switch
Result: The platform should raise smoothly, free of hesitation.
34Push in the control activate button and rotate the up/down switch to the DOWN position.
Result: The platform should lower.
Test the
35Pull and hold the function enable lever on either side.
36Press the thumb rocker switch and drive the machine in the reverse direction.
37Press the
Result: The machine should travel in the forward direction.
Part No.48643 | Genie IWP Super Series | 15 |