Starting the Engine
1At the ground controls, turn the key switch to the desired position.
2Be sure both ground and platform control red Emergency Stop buttons are pulled out to the on position.
Gasoline/LPG models
3Choose fuel by moving the fuel select switch to the desired position.
4Move the engine start toggle switch to either side. If the engine fails to start or dies, the restart delay will disable the start switch for 3 seconds.
Diesel models
3Move the glow plug switch (if equipped) to either side and hold for 3 to 5 seconds.
4Move the engine start toggle switch to either side. If the engine fails to start or dies, the restart delay will disable the start switch for 3 seconds.
OPERATING INSTRUCTIONS
All models
If engine fails to start after 15 seconds of cranking, determine the cause and repair any malfunction. Wait 60 seconds before trying to start again.
In cold conditions, 20°F /
In extreme cold conditions, 0°F /
Gasoline/LPG models: In cold conditions, 20°F /
Emergency Stop
Push in either the ground or platform red Emergency Stop button to the off position to stop all functions and turn the engine off.
Repair any function that operates when the red Emergency Stop button is pushed in.
Selecting and operating the ground controls will override the platform red Emergency Stop button.
Part No. 1000209 | 25 |