Operator's Manual | Sixth Edition · Second Printing | |
|
|
|
|
|
|
OPERATING INSTRUCTIONS
Drive Enable
Light on indicates that the primary boom has moved just past either
To drive, hold the drive enable switch to either side and slowly move the drive control handle off center.
Be aware that the machine may move in the opposite direction that the drive and steer controls are moved.
Always use the | Blue | |
| ||
direction arrows on the platform |
| |
controls and drive chassis to |
| |
identify the direction the | Yellow | |
machine will travel. | ||
|
Drive Speed Select
·Machine on incline symbol: Low range operation for inclines
·Machine on level surface symbol: High range operation for maximum drive speed
Engine Idle Select (rpm)
Select engine idle (rpm) using the symbols on the control panel.
When the foot switch is not pressed, the engine will idle at its lowest rpm.
·Turtle symbol: foot switch activated low idle
·Rabbit symbol: foot switch activated high idle
Generator (if equipped)
To start the generator, move the generator toggle switch to the on position.
Plug a power tool into the power to platform GFCI outlet.
To turn off the generator, move the generator toggle switch to the off position.
Note: Machine functions will not operate while the generator is running and the foot switch is not pressed down. When the foot switch is pressed down, the generator will turn off and the machine functions will operate.
28 | Part No. 1000209 |