DEGAUSSING COIL ATTACHMENT SPECIFICATION.

DEGAUSSING COIL ATTACHMENT SPECIFICATION.

For The Model 1493 Video Monitor.

Use degaussing coil part number CPS1766.

ATTACH THE

GROUNDING

STRAP FIRST.

With the degaussing coil leads centered on the bottom of the CRT, FORM THE COIL to avoid the remote control board.

INSTALL A WIRE TIE through the top hole in the left CRT ear.

INSTALL A WIRE TIE through the top hole in the right CRT ear.

INSTALL WIRE TIES through

INSTALL WIRE TIES through

the bottom hole in the left CRT ear.

the bottom hole, with the

 

grounding strap spring, in the

 

right CRT ear.