Genius 2093, ISO XFR-75W, 1493, 2793, 3693, 1793, 1993 Retrace, Lines, Monitor, Shuts, Down, Power

Models: ISO XFR-100W

1 114
Download 114 pages 56.31 Kb
Page 81
Image 81
Retrace

Problem

 

Tests

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Probable Solution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Retrace

1.

Turn down M. Gain to minimum.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure voltage, auto bias IC

927

 

 

 

If any of the voltages are

Lines .

 

 

 

 

 

pins 2, 4, & 6 for 5.5V to 6.5V.

 

not in the listed voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

Also measure voltage, pins 3, 5,

 

range, replace IC

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

 

927

 

 

 

 

 

 

 

 

 

 

 

 

 

 

& 7 for 1.1V to 2.7V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Measure voltage, LM324

 

 

 

 

 

 

 

 

 

 

 

 

If old style C-Film (no solder

 

 

920

 

 

 

 

 

 

 

 

connection) & pin 5 voltage is 4.8V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pin 5. Should be less than 4.5V.

add a 7.15K resistor pins 8 to 11.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Otherwise replace C-Film.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Check video gain line (J

 

 

 

)

 

 

 

 

 

 

If either V. or H. blanking is

 

 

 

 

 

 

 

 

 

 

 

 

215

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

scope sync on Vs

 

, .2mS/cm,

missing, go to that circuit for

 

 

215

 

 

and verify V. & H. blanking.

 

 

 

 

 

 

 

 

further tests.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem

 

Tests

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Probable Solution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

If screen turns bright & shutdown.

Check voltage across cap.

 

 

5-10V

Monitor

846

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shuts

2.

If shutdown right after power up.

Check V+, Hfo, & EHT at power up.

Down.

3.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disable fault; clip

 

 

 

to GND.

If solution, check fault circuit.

019

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Disable shutdown; clip V- to

 

 

.

 

 

Measure EHT, should be less than 27KV.

 

 

109

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Problem

 

Tests

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Probable Solution

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

With power applied, check voltage

If 0V to 100V, ohm out fuse

 

&

No

146

 

ground to (V-) anode of diode

 

 

 

 

 

.

 

 

inrush current limiter

 

 

 

 

25Ω

 

to .5Ω .

 

156

 

 

159

 

 

 

Power.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Measure voltage, V+ line is 0V &

Ohm out crowbar zener diode

 

 

 

 

 

.

 

181

 

 

PS chirps

 

 

 

 

 

 

 

 

 

 

 

 

Also ohm out H. output Xsr

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

433

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

If fuse is blown.

 

 

 

 

 

 

 

 

 

 

 

 

If the zener is shorted and the fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

is blown, replace fuse

146

 

,

 

 

 

 

 

 

 

 

 

 

 

 

 

Ohm out 160V crowbar zener

 

 

181

.

zener

181

, power FET

136

,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and the C5184 IC

 

 

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

If the power supply chirps and

Ohm out the 17V line; V- to anode

 

 

high voltage can be heard.

 

 

 

 

 

 

 

 

of

141

,

141

,

149

,

139

 

,

 

132

 

 

,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J-Film pins 8-14 & IC

 

115

 

 

pin 15.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.

If the power supply chirps, check

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for shorted secondary voltages by;

First, ohm out diodes;

 

 

 

 

 

 

 

 

 

,

 

 

 

 

 

 

 

 

 

,

 

 

 

 

142

 

 

168

 

 

 

 

Disconnect power to chassis.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

,

 

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

169

 

 

181

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Apply external DC PS to 16V

 

 

 

 

 

 

 

 

If PS current less than .5A and 12V

 

 

line at cathode of diode

 

 

.

 

 

 

 

 

 

 

 

line=11.5V to 12.5V, go to next test.

 

 

 

169

 

 

 

 

 

 

 

 

 

 

Apply second DC voltage to 24V

If PS current less than .3A, line OK.

 

 

line at cathode of

 

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

Check base of H. output

 

433

 

 

 

for

 

 

168

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

drive waveform. If OK connect 24V

 

 

FBT Check at low voltage;

 

 

 

 

 

 

 

 

line to V+ line and check flyback

 

 

 

 

 

 

 

 

 

 

waveform at collector of

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

433

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Without H. deflection load,

 

PS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

chirps) If large and small pulses

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

observed, replace the FBT.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

97

Page 81
Image 81
Genius 2093, ISO XFR-75W, 1493, 2793, 3693, 1793, 1993, ISO XFR-100W manual Retrace, Lines, Monitor, Shuts, Down, Power