3

RF OUTPUT

50 OHM 250W

16

REMOTE CONTROL

SCA 2

 

 

1 GND

MONO

50

MPX

SCA 3

SCA 1

2 +

 

75

6

7

8

 

3 -

 

S

14

 

 

 

4

 

 

 

 

 

 

 

9

10

11

 

13

 

12

15

INTERLOCK

 

 

 

 

 

 

 

5

 

 

 

 

MAINS V

 

 

 

 

 

 

 

WARNING

 

 

 

 

 

 

 

Voltages under equipment cover plate

 

A

 

 

 

can be hazardous to your life. Equipment

 

 

1

CE

only can be handled by qualified personnel.

 

 

2

 

1 - MAIN SUPPLY CONNECTOR

2 - AC FUSE 3A

3 - FAN

4 - DB 9 PIN INPUT / OUTPUT CONNECTOR FOR TELEMETRY ( opt.01 )

5 - BNC FEMALE FOR CONNECTION OF THE INTERLOCK LOOP - A CONNECTION TO GROUND INHIBIT RF POWER 6-7-8- BNC FEMALES FOR SUBCARRIERS GENERATORS INPUTS

9-10-11- SCA INPUT ADJUSTING LEVELS

12 - XLR FEMALE BALANCED MODE MONO AUDIO INPUT

13 - MONO INPUT ADJUSTING LEVEL

14 - BNC FEMALE FOR THE COMPOSITE MPX INPUT

15 - MPX INPUT ADJUSTING LEVEL

16 - N FEMALE FOR RF OUTPUT POWER

TITLE

NICOM

Nt250 EXCITER

REAR PANEL LAYOUT

DATE

JULY 2001

DRAWING NO.

Nt250 Rear Panel.cdr

Page 14
Image 14