| Specifications |
| Model HR2527A |
| Axial Pump |
Volume HR2527A | 2.5 GPM |
Maximum Discharge Pressure | 2750 PSI |
Maximum Inlet Pressure | Up to 90 PSIG1 |
RPM | 3450 |
Plunger Diameter | 16mm |
Stroke | 5.3mm (7.1 o angle) |
Crankcase Oil Capacity | 4.5 fl. oz. |
Temperature of Pumped Fluids | Up to 80 oF |
Inlet Port | 1 x 1/2" NPT |
Discharge Ports | 3/8" NPT |
Shaft Rotation | Clockwise |
Weight | 11.7 lbs. (12.7 lbs.) |
Width | |
Height | |
Swash Plate Bore | 3/4" x 3/16" Keyway |
Valve Type | Polyamide Plastic |
1 | A 25 PSIG minimum inlet pressure is required. |
|
HR2527A ELECTRIC HORSEPOWER
REQUIREMENTS
RPM | GPM | 1000 PSI | 1500 PSI | 2000 PSI | 2750 PSI |
3450 | 2.5 | 1.7 | 2.6 | 3.4 | 4.7 |
HORSEPOWER RATINGS: The rating shown are the power
requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.
HR2527A GAS HORSEPOWER
REQUIREMENTS
RPM | GPM | 1000 PSI | 1500 PSI | 2000 PSI | 2750 PSI |
3450 | 2.5 | 2.3 | 3.4 | 4.5 | 6.3 |
We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horse- power requirements, use the Follow- ing formula:
Electric HP = (GPM X PSI) / 1460 Gas HP = (GPM X PSI) / 1100
3