Giant HR3030, HR2527A, HR3025 Pump Trouble Shooting, leaks, correctlysized inlet plumb

Models: HR3030 HR3025 HR2527A

1 12
Download 12 pages 28.34 Kb
Page 9
Image 9
PUMP TROUBLE SHOOTING

PUMP TROUBLE SHOOTING

MALFUNCTION

CAUSE

REMEDY

The Pressure and/or

Worn packing seals

Replace packing seals

theDeliveryDrops

Brokenvalvespring

Replacespring

 

Worn or Damaged nozzle

Replacenozzle

 

Fouleddischargevalve

Cleanvalveassembly

 

Fouledinletstrainer

Cleanstrainer

 

Worn or Damaged hose

Repair/Replacehose

 

Worn or Plugged relief valve on pump

Clean,Reset,andReplacewornparts

 

Cavitation

Check suction lines on inlet of

 

 

pumpforrestrictions

Water in crankcase

Highhumidity

Reduceoilchangeinterval

 

Worn seals

Replaceseals

Noisy Operation Wornbearings

Cavitation

Replacebearings,Refillcrankcase oilwithrecommendedlubricant Checkinletlinesforrestrictions and/orproper sizing

Rough/Pulsating

Wornpacking

Replacepacking

Operationwith

Inletrestriction

Check system for stoppage, air

Pressure Drop

 

leaks, correctlysized inlet plumb-

 

 

ing to pump

 

Cavitation

Checkinletlinesforrestrictions

 

 

and/or proper size

 

 

 

Pressure Drop at

Restricteddischargeplumbing

Re-sizedischargeplumbingto

Gun

 

flow rate of pump

 

 

 

ExcessiveLeakage

Wornplungers

Replaceplungers

 

Wornpacking/seals

Adjust or Replace packing seals

 

Excessivevacuum

Reducesuctionvacuum

 

Inlet pressure too high

Reduceinletpressure

 

 

 

HighCrankcase

Wrong Grade of oil

Giant oil is recommended

Temperature

Improper amount of oil in crankcase

Adjust oil level to proper amount