Installation Instructions
Step 2: Connect to gas supply
1.The inlet to the appliance is ISO 7 - Rp 1⁄2” internal thread situated towards the top right corner of the rear.
2.Fit the bayonet connection to the wall in the shaded area as shown.
The shaded area shown is applicable to installati ons in minimum depth cabinets.
If more room is available, the bayonet fixing area can be extended, provided that the flexible tube does not obscure the fan intake.
60mm |
|
| 60 |
rear | mm |
60mm | |
wall | square |
3.Use a 900mm - 1125mm length of flexible connector. The flexible connector shall be fitted such that it cannot come into contact with a moveable part of the housing unit (eg; drawer) and does not pass through any space susceptible of becoming congested. Make sure that the flexible connector does not block the cooling fan inlet.
4.Flexible connections should be to BS669. Parts of the appliance likely to come into contact with a flexible connecter have a temperature rise less than 70˚C.
5.Rigid connections must be accessible to disconnect for servicing. Cut a 150mm square hole in the right hand rear corner of the support shelf for the supply pipe.
6.Make sure all connections are gas sound.
Important: - ensure that you route all mains and electrical cables and flexible tubing well clear of any adjacent heat source.
33