Installation Instructions
Before you start : Please read the
instructions. Planning your installation will
save you time and effort.
Prior to installation, ensure that the local
distributionconditions(nature of thegas and
gas pressure) and the adjustment of the
appliance are compatible. Theadjustment
conditions are stated on the data badge.
Thisapplianceis notconnectedtoa combustion
evacuationdevice. It shall be installed and
connected in accordance with current
installation regulation. Particular attention
shall be given to the relevant requirements
regarding ventilation.
In your own interest and that of safety, it is
the law that all gas appliances be installed
and serviced by competent persons. GAS
SAFE registered installers undertake to
work to satisfactory standards.
Where regulations or standards have been
revised since this handbook was printed,
always use the latest edition.
In the UK the regulations and
standards are as follows:
1. Gas Safety Regulations (Installation
and Use).
2. Building Regulations - Issued by the
Department of the Environment.
3. Building Standa rds (Scotland)
(Consolidated) - Issued by the Scottish
Development Department.
4. The current I.E.E. Wiring Regulations.
5. Electricity at Work Regulations.
6. BS 6172 Installation of Domestic Gas
cooking Appliances
7. Installation & Servicing Instructions for
this appliance.
For installation in countries other than the
UK, the appliance must be connected in
accordancewith all local gas and electrical
regulations. In the Republic of Ireland,
Installers should refer to IS813 Domestic
Gas Appliances.
Ventilation Requirements
The room containing the appliance should
have an air supply in accordance with
BS 5440: Part 2.
Allrooms require anopenable window,
or equivalent, and some rooms will
require a permanent vent as well.
For room volumes up to 5m3an air
vent of 100cm2is required.
If the room has a door that opens directly
to the outside, or the room exceeds
10m3, NO AIR VENT is required.
For room volumes between 5m3and
10m3an air vent of 50cm2is required.
Ifthere are otherfuel burningappliances
in the same room, BS 5440: Part 2
should be consulted to determine the
air vent requirements.
This appliance must not be installed in
abed sitting room of less than 20m3or
in a bathroom or shower room.
Windows and permanent vents should
thereforenot be blockedor removed without
first consulting a GAS SAFE gas installer.
In the Republic of Ireland, refer to relevant Irish
Standards for correct ventilation requirements.
Failure to install appliances correctly
is
dangerous and c ould lead to
prosecution .
This appliance i s not
connected to a com bustion produc ts
evacuationdevice. It shall be installed and
connected in accordance with curre nt
installationregulations. Particular attention
shall be given to the relevant requirements
regarding ventilation.
24