Glen Dimplex Home Appliances Ltd BI 90 G manual Cooling fan, For your safety, Ventilation

Models: BI 90 G

1 36
Download 36 pages 35.72 Kb
Page 5
Image 5

Introduction

The cooling fan

The cooling fan helps to keep the exterior cool during normal use. When a burner is operated, you should hear the cooling fan switch on automatically and be able to feel air evacuating from the appliance vents just below the fascia. The cooling fan will continue to operate for approxima tely 10 minutes after turning off the burners. This is normal.

If there is no such indication that the fan is operating, the appliance will require servicing. DO NOT USE THE APPLIANCE UNTIL IT HAS BEEN SERVICED. Switch the appliance off at the mains and contact Customer Support.

For your safety

This appliance has a built in safety device to isolate the gas and electric supplies to various components in the event of fan failure.

If the programmer/clock and lights do not function, and the ignition system stops working, the safety device has operated. Within an hour, the safety devicewillreset itselfandthe programmer /clock display will flash.

To reset the programmer/clock, pree the Plus and Minus buttons together for a few secods. When the ‘●‘ is flashing in between the hour and minutes on the LED, reset the time of day.

If when a burner control is turned on, the fan does not operate in the normal way, then the appliance will require

servicing. DO NOT USE THE APPLIANCE UNTIL IT HAS BEEN SERVICED. Switch the appliance off at the mains and contact Customer Support.

Continued use of the appliance without it being serviced could result in excessive temperatures being generated, which in turn could reduce the life of certain components.

Ventilation

The use of a gas cooking appliance resultsinthe productionof heatand moisture in the room in which it is installed. Ensure that the kitchen is well ventilated; keep natural ventilation holes open or install a mechanical ventilation device (mechanical ventilator).

Prolonged intensive use of the appliance may call for additional ventilation, for example opening a window, or more effective ventilation, for example increasing the level of mechanical ventilation where present.

This appliance is not connected to a combustion productsevacuation device. It must be installed and connected in accordance with current installation regulations. Particular attention must be given to the relevant regulations regarding ventilation.

3

Page 5
Image 5
Glen Dimplex Home Appliances Ltd BI 90 G manual Cooling fan, For your safety, Ventilation