Glen Dimplex Home Appliances Ltd FSG 60 DO/DOP manual Technical Data, Grill - Electric

Models: FSG 60 DO/DOP

1 32
Download 32 pages 53.9 Kb
Page 29
Image 29
Technical Data

Technical Data

Data badge - Lower part of front frame

Type of gas - This cooker must be used with Natural Gas only

Gas category - Natural Gas - I2H,

Pressure setting

G20 Natural Gas @ 20 mbar

Pressure test point - Use the oven injector

Aeration - Fixed

Appliance class - Class 1, freestanding

Grill - Electric

Hob - Burners have burner heads and caps which are removable for cleaning. Concealed electrodes to each burner.

Ovens - Oven burners are sheet steel, with pierced ports in stainless steel flame strip. Spark Gap: 3 - 4mm. Flame super- vision: Thermoelectric type. Thermostat phial: Rear right hand side of oven.

Electrical supply 220 - 240V ~ 50Hz

Warning: This cooker must be earthed.

Load (wattage): 1585W-1885W

Countries of destination - GB - Great

Britain,

27

Page 29