Adjusting the exhaust direction:

1.The brad nailer/stapler is equipped with an adjustable direction exhaust deflector (1). Simply adjust the directional exhaust deflector so that

the exhaust air blast will be directed away from the operator. Grasp the deflector and rotate it to the desired position for the current application.

Adjusting the fastening depth:

1.Regulate the air pressure to 120 PSI at the compressor.

2.Connect the air hose to the nailer/stapler and test for penetration by driving fasteners into a sample piece of wood. If the fasteners do not achieve the desired depth, rotate the depth adjustment thumb wheel (10) until the desired depth is achieved.

Clearing a jam:

1.Disconnect the air supply from the nailer/stapler and remove all fasteners from the magazine.

2.Remove the 3 hex screws located in driver safety cover

(8). Remove the driver safety

cover (8) so the jammed fastener is exposed.

3.Remove the jammed fastener, using screwdriver or long nose pliers if required.

4.Place the driver safety cover back onto the driving mechanism and tighten the 3 screws to secure with a hex key.

5.Test the brad nailer/stapler.

Air source

This tool is designed to operate on clean, dry, compressed air at regulated pressures between 60 and 120 PSI.

The preferred system would include a filter, a pressure regulator, and an automatic oiler located as close to the tool as possible.

All compressed air contains moisture and other contaminates that are detrimental to internal components of the tool. An air line filter will remove most of these contaminates and significantly prolong the life of the tool. If an in-line oiler is not available, place 3 - 4 drops of non detergent oil into the tool’s air inlet at the beginning of each workday.

DANGER. All air line components (hoses, connectors, filters, regulators, etc.) must have a minimum working pressure rating of at least 120 PSI or 150% of maximum system potential, whichever is greater.

14