PRoDUcT SPeciFicATionS PRoDUcT SPeciFicATionS
SS-GPC13H www.goodmanmfg.com 33
wiRing DiAgRAm — gPc1360h41Bc
Wiringissubjectto change.Always
refertothe wiring diagram or the
unitforthemostup-to-datewiring. WarninG
High Voltage:Disconnect all power before servicing or installing this unit. Multiple power
sourcesmaybepresent.Failuretodosomaycausepropertydamage,personalinjury,ordeath.









THE GOODMAN FAMILY OF
COMPANIES
®
   

 
    6s
  
  


 

 
2
3
NOTE #2
WH
NOTE #4
EM
TR
24V
208-240
3
CONTROL
240
208-240/1/60
SUPPLY VOLTAGE
C
COMP
C
S.A.
S
T1
R
L1
C
NOTE #4
H
F
RCCF
CM
T2 C
L2
BOX
H
RCCF
F
C
YL
BR
PU
2
24V
208
TR
C
BK
1
PU
COMP
CM
BR
BR
41
PLF
PU
BK YL
S
BK
RD
BK
5
6
2
3
CR
LVJB
RD
BL
BR
WH
GR
YL
R
C
W2
W1
G
Y
A
T
O
T
S
M
R
E
H
T
T2
T1
RD
BL
NOTE #3
PU
BL
L1
GND
C
L2
PU
BK
60
/
/
1
0
4
2
-
8
0
2
7
8
9
BL
BR
208-240/1/60 0140G00407
RD
RD
BK
BK
RD
YL
C L G N
12 3
BL
BL
RD
RD
GR
GR
GR
EM
GR
SEE NOTE 2

1
L
3 1
2
RW2 W1 Y G C
4
5
6
PLF
C
SEE NOTE #2
IF USED
THERMOSTAT
N
G
SEE UNIT RATING PLATE FOR TYPE AND SIZEOF OVER CURRENT PROTECTIONCOMPONENT LEGENDCCMCOMPEMGNDLVJBPLFRCCFSATRCONTACTORCONDENSER MOTORCOMPRESSOREVAPORATOR MOTOREQUIPMENT GROUNDLOW VOLTAGE JUNCTION BOXFEMALE PLUG / CONNECTORRUN CAPACITOR FORCOMPRESSOR AND FANSTART ASSISTTRANSFORMER WIRE CODEBK BLACKBL BLUEBR BROWNGR GREENOR ORANGEPU PURPLERD REDWH WHITEYL YELLOWFACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTINAL HIGH VOLTAGEFIELD WIRING HIGH VOLTAGE LOW VOLTAGENOTES:1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE ENERGIZED, THE HIGHER SPEED SETTING IS USED.3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.4. START ASSIST FACTOR EQUIPED WHEN REQUIRED5. USE COPPER CONDUCTORS ONLY.++ USE N.E.C. CLASS 2 WIRE
EM
1C
2 3
SEE NOTE 5
YL
RD
SA
(IF USED) SEE NOTE 4
YL
WH
BK
PU
45
WH
WH
YL
BK
