WARNING

TO PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH, DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLIANCE.

WARNING

HIGH VOLTAGE!

INSTALLATION AND REPAIR OF THIS UNIT SHOULD BE

PERFORMED ONLY BY INDIVIDUALS MEETING (AT A

MINIMUM) THE REQUIREMENTS OF AN “ENTRY LEVEL

TECHNICIANAS SPECIFIED BY THE AIR CONDITIONING,

HEATING, AND REFRIGERATION INSTITUTE (AHRI).

ATTEMPTING TO INSTALL OR REPAIR THIS UNIT WITHOUT

SUCH BACKGROUND MAY RESULT IN PRODUCT DAMAGE,

PERSONAL INJURY OR DEATH.

GENERAL INFORMATION

WARNING

TO PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR DEATH, DUE TO FIRE, EXPLOSIONS, SMOKE, SOOT, CONDENSATION, ELECTRIC SHOCK OR CARBON MONOXIDE, THIS UNIT MUST BE PROPERLY INSTALLED, REPAIRED, OPERATED, AND MAINTAINED.

This unit is approved for outdoor installation ONLY. To assure that your unit operates safely and efficiently, it must be installed, operated, and maintained in accordance with these installation and operating instructions, all local building codes and ordinances.

EPA REGULATIONS

IMPORTANT: THE UNITED STATES ENVIRONMENTAL PROTECTION AGENCY (EPA) HAS ISSUED VARIOUS REGULATIONS REGARDING THE INTRODUCTION AND DISPOSAL OF REFRIGERANTS IN THIS UNIT. FAILURE TO FOLLOW THESE REGULATIONS MAY HARM THE ENVIRONMENT AND CAN LEAD TO THE IMPOSITION OF SUBSTANTIAL FINES. BECAUSE REGULATIONS MAY VARY DUE TO PASSAGE OF NEW LAWS, WE SUGGEST A CERTIFIED TECHNICIAN PERFORM ANY WORK

DONE ON THIS UNIT. SHOULD YOU HAVE ANY QUESTIONS PLEASE CONTACT THE LOCAL OFFICE OF THE EPA.

NATIONAL CODES

This product is designed and manufactured to permit instal- lation in accordance with National Codes. It is the installer’s responsibility to install the product in accordance with Na- tional Codes and/or prevailing local codes and regulations.

The heating and cooling capacities of the unit should be greater than or equal to the design heating and cooling loads of the area to be conditioned. The loads should be calculated by an approved method or in accordance with ASHRAE Guide or Manual J - Load Calculations published by the Air Condi- tioning Contractors of America.

Obtain from:

American National Standards Institute

1430 Broadway

New York, NY 10018

System design and installation should also, where applicable, follow information presented in accepted industry guides such as the ASHRAE Handbooks. The manufacturer assumes no responsibility for equipment installed in violation of any code or regulation. The mechanical installation of the packaged roof top units consists of making final connections between the unit and building services; supply and return duct con- nections; and drain connections (if required). The internal systems of the unit are completely factory-installed and tested prior to shipment.

Units are generally installed on a steel roof mounting curb assembly which has been shipped to the job site for installa- tion on the roof structure prior to the arrival of the unit. The model number shown on the unit’s identification plate identi- fies the various components of the unit such as refrigeration tonnage, heating input and voltage.

Carefully inspect the unit for damage. Any bolts or screws which may have loosened in transit must be re-tightened. In the event of damage, the receiver should:

1.Make notation on delivery receipt of any visible damage to shipment or container.

2.Notify carrier promptly and request an inspection.

3.In case of concealed damage, carrier should be notified as soon as possible-preferably within 5 days.

4.File the claim with the following supporting documents:

a.Original Bill of Lading, certified copy, or indemnity bond.

b.Original paid freight bill or indemnity in lieu thereof.

c.Original invoice or certified copy thereof, showing trade and other discounts or reductions.

d.Copy of the inspection report issued by carrier representative at the time damage is reported to the carrier. The carrier is responsible for making prompt inspection of damage and for a thorough investigation of each claim. The distributor or manufacturer will not accept claims from dealers for transportation damage.

NOTE: When inspecting the unit for transportation damage, remove all packaging materials. Recycle or dispose of the packaging material according to local codes.

PRE-INSTALLATION CHECKS

Carefully read all instructions for the installation prior to in- stalling unit. Ensure each step or procedure is understood and any special considerations are taken into account be- fore starting installation. Assemble all tools, hardware and supplies needed to complete the installation. Some items may need to be purchased locally.

3

Page 3
Image 3
Goodman Mfg IO-367B installation instructions General Information, EPA Regulations, National Codes, PRE-INSTALLATION Checks

IO-367B specifications

Goodman Manufacturing, a well-respected name in the HVAC industry, offers an impressive range of products tailored to enhance energy efficiency and comfort in residential environments. Among their standout offerings is the IO-367B model, a heat pump designed to deliver exceptional performance, reliability, and user-friendly features.

The Goodman IO-367B is a split system heat pump that provides both heating and cooling capabilities, making it a versatile choice for homeowners looking to maintain an optimal indoor climate year-round. Its sleek design allows for easy installation and integration into existing systems, ensuring minimal disruption during the setup process.

One of the key features of the IO-367B is its energy efficiency. With a high SEER (Seasonal Energy Efficiency Ratio) rating, it operates smoothly and effectively while keeping energy consumption low. This not only leads to lower utility bills for homeowners but also supports environmentally friendly practices by reducing the overall carbon footprint. The unit is compliant with the latest energy regulations, making it a future-proof investment for those who prioritize sustainability.

The IO-367B employs advanced technology, including a multi-speed compressor that adjusts operation to meet the specific heating or cooling demands of a space. This feature enhances comfort by reducing temperature fluctuations and maintaining a consistent climate. Additionally, its sound-dampening features ensure quieter operation, making it an excellent choice for both indoor and outdoor installations.

Other notable characteristics include the durable construction of the heat pump, which is designed to withstand varying weather conditions. Its corrosion-resistant cabinet enhances longevity and reliability, ensuring that homeowners can depend on their system for years. Furthermore, Goodman provides a generous warranty on the IO-367B, reflecting their confidence in the product’s durability and performance.

In conclusion, the Goodman IO-367B heat pump stands out in the market due to its energy efficiency, advanced technology, and sturdy design. Ideal for those seeking to enhance their home's comfort while being mindful of energy consumption, this model is a reliable solution for heating and cooling needs.