Goodman Mfg SS-CPG36-72 warranty Product Specifications, Multiple injury, or, present, sources may

Models: SS-CPG36-72

1 40
Download 40 pages 7.92 Kb
Page 35
Image 35
Manual background

Product Specifications

Wiring Diagram CPG036-600904B/7B — CPG036*4B/7B — CPG072*4B/7B (460V/575v, Belt Drive)

T3 T2

T1

COMP

 

PU

BR

BK

CM

EM

 

 

BC GR

BK

T1

C

RD

T2

OR

T3

L3 L2 L1

RD

 

 

 

 

 

 

YL

 

 

 

 

 

RD

BK

 

 

 

 

 

GND

PU

 

 

 

 

 

 

 

 

 

 

 

BK

T1

 

T2

T3

 

 

 

 

 

 

BL

 

 

 

 

 

YL

BL

L1

C

L2

L3

 

 

 

 

 

 

 

 

BK

 

 

OR

 

POWER SUPPLY

 

 

 

 

 

 

 

 

 

 

460/3/60

BK

 

 

 

 

 

575/3/60

 

 

 

 

 

 

SEE NOTE 4

RD

 

 

 

 

 

BK

BK

 

 

 

 

 

 

OR

OR

 

 

 

 

 

BK OR

 

3

 

1

2

3

460/575

 

2

460

 

C

 

BL

 

TR

 

1

TR

 

 

575

 

240

 

 

 

 

 

 

 

VMR

LS

24V

 

 

 

 

 

 

 

 

 

RD

 

 

 

 

RD WH

RD

BL

BL

GR

 

 

 

 

 

 

 

 

 

 

PK

 

 

 

 

 

BK

S1

 

 

 

 

 

 

 

 

 

 

 

RD

 

SMOKE/FIRE

 

 

 

 

DETECTOR

 

 

 

TB1

 

REPLACES JUMPER

 

 

S2

WIRE

 

 

 

OR

BR

 

 

 

 

power death.

Multiple injury, or

 

OR

ALS

BL

 

PU

PS

 

PU

YL

 

 

YL

Manual background ORManual background

ECON

 

RD

 

 

 

GR

 

RD

 

 

 

RD

1

4

7

10

 

BL

2

5

8

11

 

PU

3

6

9

12

YL

YL

WH

YL

 

YL

installing this unit. damage, personal

 

NOTE 2

 

 

 

PLF

 

 

 

RS

 

 

 

OR

 

3

6

YL

 

 

2

5

 

 

 

1

4

 

 

 

 

YL

 

PU

W. R.

(ALT.) HONEYWELL

 

 

GAS VALVE

GAS VALVE

 

 

PU

MV

 

 

GV

 

GV

 

 

BL

MV

 

WH

BL

 

BR

VM

FS Manual background

Manual background IGNManual background

FS

DI

BL

RD

L1

 

 

PU

L2

HEATUNUSED

 

BL

 

 

BL

 

WH

BL

COOL

YL BL RD

GR BL

 

BR

 

Y Y1 C R W W2 G

WH

TO THERMOSTAT

SEE

 

NOTE 5

RD

 

OR

 

Manual background RDManual background

WH

Manual background BR

SEE

NOTE 3

Manual backgroundGR

GR

IIC

YL/PK

BK

LPS

HPS

BL/PKManual background

power before servicing or Failure to do so may cause property

BK

BR

RD

FC

all

present.

L1

 

 

SUPPLY VOLTAGE

 

 

L2

 

 

L3

 

 

 

 

208-240/3/60

 

 

 

 

 

 

C

 

 

 

 

 

T2

C

 

 

 

 

 

T1

 

 

T2

 

 

 

 

L2

 

 

 

L1

 

T1 COMP

 

 

 

 

 

 

 

 

 

 

 

 

 

T3

 

 

T3

 

 

 

 

L3

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

FC

 

CM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

PCB

 

EM

 

FC

 

 

 

 

 

PCB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL

 

 

 

 

 

SEE NOTE 2

 

VM

DI

LI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

2

1

 

 

 

 

 

 

 

 

 

TB1

 

 

TR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IGN

 

 

 

IIC

 

F

 

 

 

FS

 

 

FS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

LS

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALS

RS

 

 

 

 

 

IIC

 

3

 

 

 

 

 

GV

 

 

 

 

 

 

6

 

 

PS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECON

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

7

 

10

12

 

 

 

 

 

 

 

 

 

 

 

 

11 LPS

HPS

 

C

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

 

 

 

 

 

 

 

 

4

6

5

4

 

 

 

 

 

 

 

 

 

 

 

 

R

G

 

W

 

 

Y1 Y2

 

C

 

3

2

1

 

 

 

 

TB1

PLF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO THERMOSTAT Manual backgroundManual background

TERMINAL BLOCK

INSTALLER/SERVICEMAN

THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:

STATUS LIGHT

EQUIP. STATUS

CHECK

ON

NORMAL OPERATION

-

OFF

NO POWER OR

CHECK INPUT POWER

 

INTERNAL CONTROL

CHECK FUSE ON CONTROL

 

FAULT

REPLACE CONTROL

1 BLINK

IGNITION FAILURE

GAS FLOW

 

OR

GAS PRESSURE

 

OPEN ROLLOUT

GAS VALVE

 

SWITCH

FLAME SENSOR

 

OR

FLAME ROLLOUT

 

OPEN AUX. LIMIT

BAD SWITCH

 

SWITCH

AUX. LIMIT OPEN

2 BLINKS

PRESSURE SWITCH

CHECK

 

OPEN

PRESSURE SWITCH

3 BLINKS

PRESSURE SWITCH CLOSED

CHECK

 

WITHOUT INDUCER ON

PRESSURE SWITCH

4 BLINKS

OPEN LIMIT SWITCH

MAIN LIMIT OPEN

 

 

BAD SWITCH

5 BLINKS

FALSE FLAME SENSED

STICKING GAS VALVE

6 BLINKS

COMPRESSOR

3 MIN. COMP.

 

OUTPUT DELAY

ANTI-CYCLE TIMER

COMPONENT LEGEND

ALS

AUXILIARY LIMIT SWITCH

COMP

COMPRESSOR

CM

CONDENSER MOTOR

C

CONTACTOR

EM

EVAPORATOR MOTOR

F

FUSE

FC

FAN CAPACITOR

FS

FLAME SENSOR

GND

EQUIPMENT GROUND

GV

GAS VALVE

HPS

HIGH PRESSURE SWITCH

IIC

INTEGRATED IGNITION CONTROL

IGN

IGNITOR

LS

LIMIT SWITCH

LPS

LOW PRESSURE SWITCH

PLF

FEMALE PLUG/CONNECTOR

PS

PRESSURE SWITCH

RS

ROLLOUT SWITCH

TB1

TERMINAL BLOCK (24V SIGNAL)

TR

TRANSFORMER

VM

VENT MOTOR

VMR

VENT MOTOR RELAY

BC

BLOWER CAPACITOR

NOTES

 

1.REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF INSULATION AS ORIGINAL. (USE COPPER CONDUCTOR ONLY).

2.FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.

3.FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING SPEED AT COOL TERMINAL. CHANGE HEATING SPEED AT HEAT TERMINAL ON CONTROL BOARD

3 SPEED MOTOR RD - LOW SPEED BL - MED. SPEED BK - HIGH SPEED

4.ACCESSORY ECONOMIZER PLUG ADJACENT TO BLOWER HOUSING IN RETURN AIR COMPARTMENT. REMOVE MALE PLUG AND ATTACH FEMALE PLUG TO ECONOMIZER ACCESSORY.

5.USE COPPER CONDUCTORS ONLY.

USE NEC CLASS 2 WIRE.

6.PURPLE WIRE CONNECTS TO TRANSFORMER (PIN 1).

7.SPEED TAP TERMINATIONS SHOWN ON DIAGRAM ARE REPRESENTATIVE, BUT ACTUAL FACTORY SETTING MAY BE DIFFERENT BASED ON HEATING VALUE AND CAPACITY OF UNIT.

8.TO RUN DIFFERENT SPEED FOR HEATING AND COOLING, DISCONNECT GEEEN JUMPER FROM "COOL" TERMINAL AND REPLACE WITH APPROPRIATE SPEED TAP. THEN PLACE DISCONNECTED END OF JUMPER ON "UNUSED" TERMINAL LEFT OPEN BY MOVING THE SPEED TAP.

9.FOR LOW STAGE OPERATION ONLY, REMOVE WHITE JUMPER. FOR 2 STAGE OPERATION, REMOVE JUMPER AND CONNECT W2 TO W1 ON THERMOSTAT.

SEE UNIT RATING PLATE FOR TYPE AND SIZE OF OVERCURRENT PROTECTION.

208-240/3/60 0140L00507 REV B

FACTORY WIRING

LINE VOLTAGE

LOW VOLTAGE

OPTIONAL

HIGH VOLTAGE

 

 

FIELD WIRING

 

 

HIGH VOLTAGE

 

 

LOW VOLTAGE

 

 

WIRE CODE

BK

BLACK

BL

BLUE

BR

BROWN

GR

GREEN

OR

ORANGE

PK

PINK

PU

PURPLE

RD

RED

WH

WHITE

YL

YELLOW

BL/PK

BLUE WITH PINK STRIP

YL/PK

YELLOW WITH PINK STRIP

THERMOSTAT

FIELD WIRING

NO ECONOMIZER

 

W

WH

W

G

GR

G

R

RD

R

Y1

 

 

Y/Y2

YL

Y

C

BL

C

TB1

 

STAT

 

 

WITH ECONOMIZER OPTION

W

WH

W

G

GR

G

R

RD

R

Y1

YL

Y

Y/Y2

 

 

C

BL

C

TB1

 

STAT

 

 

2 STAGE COOLING

 

W

WH

W

G

GR

G

R

RD

R

Y1

YL

Y1

Y/Y2

PK

Y2

C

BL

C

TB1

STAT

 

 

Disconnect

be

 

High Voltage:

sources may

 

 

 

Warning

 

Always or the wiring.

Wiring is subject to change. refer to the wiring diagram unit for the most up-to-date

SS-CPG36-72

www.goodmanmfg.com

35

Page 35
Image 35
Goodman Mfg SS-CPG36-72 warranty Product Specifications, Multiple injury, or, present, sources may, Always or the wiring