Product Specifications
Product Specifications — CPG048 B Models (cont.)
CPG048
1151DXXX
CPG048
1153DXXX
CPG048
1153BXXX
CPG048
1154BXXX
CPG048
1157BXXX
Cooling Capacity
Total BTU/h | 45,500 | 45,500 | 45,500 | 45,500 | 45,500 |
|
|
|
|
|
|
Sensible BTU/h | 35,000 | 35,000 | 35,000 | 35,000 | 35,000 |
|
|
|
|
|
|
SEER / EER | 13.0 / 11.3 | 13.0 / 11.3 | 13.0 / 11.3 | 13.0 / 11.3 | 13.0 / 11.3 |
Decibels | 78 | 78 | 78 | 78 | 78 |
AHRI Reference #s | 4385062 | 4385063 | 4385063 | 4385064 | 4397608 |
Heating Capacity |
|
|
|
|
|
|
|
|
|
|
|
Max. Input /Output kBTU/h | 115 / 92 | 115 / 92 | 115 / 92 | 115 / 92 | 115 / 92 |
|
|
|
|
|
|
Low Input /Output kBTU/h | 86.25 / 69 | 86.25 / 69 | 86.25 / 69 | 86.25 / 69 | 86.25 / 69 |
|
|
|
|
|
|
Steady State Efficiency (AFUE) | 80 | 80 | 80 | 80 | 80 |
Temperature Rise Range (°F) Hi / Low | |||||
No. of Burners | 5 | 5 | 5 | 5 | 5 |
Evaporator Motor / Coil |
|
|
|
|
|
Motor Type | Direct Drive | Direct Drive | Belt Drive | Belt Drive | Belt Drive |
|
|
|
|
|
|
Indoor Nominal CFM | 1,600 | 1,600 | 1,600 | 1,600 | 1,600 |
|
|
|
|
|
|
Motor Speed Tap (Cooling) | Medium | Medium | |||
Indoor Motor FLA (Cooling) | 2.87 | 2.87 | 3.8 | 1.9 | 2.3 |
Horsepower - RPM | ½ - 1,000 | ½ - 1,000 | 1.0 / 1,725 | 1.0 / 1,725 | 1½ / 1,725 |
Piston Size (Cooling) | 0.076 | 0.076 | 0.076 | 0.076 | 0.076 |
Filter Size (#) | 14 x 20 x 2 (4) | 14 x 20 x 2 (4) | 14 x 20 x 2 (4) | 14 x 20 x 2 (4) | 14 x 20 x 2 (4) |
|
|
|
|
|
|
Drain Size (NPT) | ¾” | ¾” | ¾” | ¾” | ¾” |
|
|
|
|
|
|
103 | 103 | 103 | 103 | 105 | |
Evaporator Coil Face Area (ft²) | 7.0 | 7.0 | 7.0 | 7.0 | 7.0 |
Rows Deep / Fins per Inch | 4 / 16 | 4 / 16 | 4 / 16 | 4 / 16 | 4 / 16 |
Belt Drive Evap Fan Data |
|
|
|
|
|
# of Wheels (D” x W”) | (1) 11 x 10 | (1) 11 x 10 | (1) 11 x 10 | ||
|
|
|
|
|
|
Motor Sheave / Blower Sheave |
| VL44 X ⅝ / AK66 X 1 |
| ||
|
|
|
|
|
|
Belt | AX55 | AX55 | AX55 | ||
|
|
|
|
|
|
Condenser Fan / Coil |
|
|
|
|
|
Quantity of Condenser Fan Motors | 1 | 1 | 1 | 1 | 1 |
Horsepower - RPM | ¼ - 1,090 | ¼ - 1,090 | ¼ - 1,090 | ¼ - 890 | ¼ - 1,075 |
Fan Diameter / # Fan Blades | 22 / 4 | 22 / 4 | 22 / 4 | 22 / 4 | 22 / 4 |
|
|
|
|
|
|
Outdoor Nominal CFM | 3,800 | 3,800 | 3,800 | 3,800 | 3,800 |
|
|
|
|
|
|
Face Area (ft²) | 17.0 | 17.0 | 17.0 | 17.0 | 17.0 |
|
|
|
|
|
|
Rows Deep/ Fins per Inch | 1 / 24 | 1 / 24 | 1 / 24 | 1 / 24 | 1 / 24 |
Compressor |
|
|
|
|
|
Quantity / Stage | 1 / Single | 1 / Single | 1 / Single | 1 / Single | 1 / Single |
Type | Scroll | Scroll | Scroll | Scroll | Scroll |
Compressor RLA / LRA | 19.9 / 109 | 13.1 / 83.1 | 13.1 / 83.1 | 6.1 / 41 | 4.4 / 33 |
|
|
|
|
|
|
Electrical Data |
|
|
|
|
|
|
|
|
|
|
|
Outdoor Fan FLA | 1.40 | 1.40 | 1.40 | 0.80 | 0.60 |
Total Unit Amps | 24.1 | 17.4 | 18.3 | 8.8 | 7.3 |
Min. Circuit Ampacity¹ | 29 | 21 | 22 | 10 | 8 |
Max. Overcurrent Protection (amps)² | 45 | 30 | 30 | 15 | 15 |
|
|
|
|
|
|
Power Supply Conduit Hole | 1.125 | 1.125 | 1.125 | 1.125 | 1.125 |
|
|
|
|
|
|
½” | ½” | ½” | ½” | ½” | |
Operating Weight (lbs) | 580 | 580 | 580 | 580 | 580 |
Ship Weight (lbs) | 605 | 605 | 605 | 605 | 605 |
¹Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or
Note: Always check the S&R plate for electrical data on the unit being installed.
6 | www.goodmanmfg.com |