Goodman Mfg SSZ140181A service manual Wiring, Diagrams, To Or

Models: SSZ140181A

1 26
Download 26 pages 60.6 Kb
Page 26
Image 26
WIRING

26

Wiring is subject to change,

CONTROL BOX

DC

 

H

DF2

 

BK

 

V

LVDR

 

D

BK

 

R

 

DF1

 

 

C Y O O W2 R R DFT

LVJB

RD R

WH W2

OR O BL/PK Y

BL C

OUTDOOR POWER SUPPLY

 

SEE RATING PLATE

 

 

NOTE 1

 

 

 

 

 

L1

T1

 

 

 

T2

5

SR 2

 

 

L2

C

1

SC

C

 

IO

 

H

C

 

COLOR CODE

BK ---------------

BLACK

BL/PK ----------

BLUE/PINK STRIPE

BR ---------------

BROWN

OR ---------------

ORANGE

DOUBLE ONLY

C

A

U

X

S

 

RCCF

 

 

 

 

 

 

COMP

 

M

 

F

 

A

 

 

I

R

 

 

N

 

 

 

 

!WARNING

WIRING

TO OR

DIAGRAMS

always refer to the wiring diagram on the unit for the most up-

BL OR WH RD

YL

BK

RD

RD

 

BK

SR

 

 

5

 

 

 

2

1

 

 

BL

 

 

YL

 

 

 

T1

T2

 

 

L1

L2

 

ALTERNATE DOUBLE

 

POLE CONTACTOR

 

 

 

 

COMP

BL/PK

HPS BL/PK

MAIN

 

 

RD

 

 

 

BK

AUX

BK

BL

YL

RVC

BL/PK

YL/PK

 

 

 

SC

 

 

BK

BK

 

RD

RD

BL

 

BL BK

BK

 

 

 

 

 

 

T1

T2 RD

 

 

 

 

 

 

 

 

 

 

L1

L2

RD

 

 

 

 

C

 

 

 

 

 

 

 

 

 

YL/PK

BK

BK

 

 

 

 

 

 

 

RD

 

 

 

 

 

 

 

 

YL

 

 

 

 

PU

HERM

 

 

 

 

 

C

YL

YL

 

 

 

RD

F

 

 

 

 

 

 

 

BR

RCCF

YL

 

 

 

 

 

 

 

 

 

 

SA

 

 

 

 

 

 

(IF USED)

 

 

 

 

 

NOTE 2

 

 

 

 

 

 

RD

 

 

BK

EQUIPMENT GROUND

USE COPPER

PU ---------------

PURPLE

RD ---------------

RED

WH --------------

WHITE

YL ---------------

YELLOW

YL/PK---------

YELLOW/PINK STRIPE

WIRING CODE

FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE

ALTERNATE POLE CONTACTOR

 

 

 

 

SA

 

 

 

 

(IF USED)

DF1 DF2

IO

A

U

X

 

 

 

HVDR

CM

M

 

 

A

 

 

 

I

 

 

 

N

FIELD WIRING

 

 

CH

 

 

 

 

 

 

 

HIGH VOLTAGE

 

(IF USED)

 

 

LOW VOLTAGE

 

NOTE 3

 

 

 

 

R

DFT

 

 

 

 

 

 

DC

 

 

 

 

 

DFT

C

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

R

LVDR

 

 

 

 

 

W2

 

 

 

COMPONENT CODE

 

 

 

 

RVC

C ---------------

CONTACTOR

 

O

 

 

 

 

 

 

CH -------------

CRANKCASE HEATER

 

 

LPS

 

C

CM ------------

OUTDOOR FAN MOTOR

 

O

 

 

 

 

COMP --------

COMPRESSOR

 

 

 

 

 

DC -------------

DEFROST CONTROL

 

 

HPS

 

 

DFT -----------

DEFROST THERMOSTAT

R

 

 

 

C

HPS-------------

HIGH PRESSURE SWITCH

 

O W2

Y

 

 

HVDR --------

HIGH VOLTAGE DEFROST RELAY

 

INDOOR POWER

 

IO --------------

INTERNAL OVERLOAD

 

 

 

SUPPLY

 

 

LPS ------------

LOW PRESSURE SWITCH

 

 

 

 

 

 

 

 

LVDR ---------

LOW VOLTAGE DEFROST RELAY

 

 

 

 

 

LVJB ----------

LOW VOLTAGE JUNCTION BOX

 

NOTES:

 

 

to-date wiring.

MAIN

YL

 

 

 

PU

C

S

AUX

 

 

BR

 

R

IO

 

 

BK

 

 

RD DFT RD

YL/PK LPS

CONDUCTORS ONLY

YL/PK

RCCF

--------- RUN CAPACITOR FOR COMPRESSOR & FAN

1) TO INDOOR UNIT LOW VOLTAGE

RVC -----------

REVERSING VALVE COIL

 

 

TERMINAL BLOCK & INDOOR

 

 

THERMOSTAT.

SA -------------

START ASSIST

 

 

2) START ASSIST FACTORY

SC -------------

START CAPACITOR FOR COMPRESSOR (OPTIONAL)

 

 

EQUIPPED WHEN REQUIRED.

3) CRANKCASE HEATER MAY BE

SR -------------

START RELAY FOR COMPRESSOR (OPTIONAL)

 

 

FACTORY OR FIELD INSTALLED.

 

 

 

 

 

 

USE N.E.C. CLASS 2 WIRE

 

 

 

 

 

 

TO ORDIAGRAMS BK Manual backgroundManual backgroundManual backgroundManual background BK Manual backgroundManual background

CM

CH

(IF USED) NOTE 3

CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.

 

 

VENDOR : GOODMAN PRINT SHOP

01/06

0140R00029P

Page 26
Image 26
Goodman Mfg SSZ140181A service manual Wiring, Diagrams, To Or