Goodman Mfg SSZ140181A service manual Heating Specifications, capacity, btuh, 19.2

Models: SSZ140181A

1 26
Download 26 pages 60.6 Kb
Page 24
Image 24
Manual background

HEATING SPECIFICATIONS

Model: SSZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1

Conditions: 1400 CFM Indoor Air @ 70°F DB

Outdoor

Basic Unit without

 

Capacity of Unit*

 

Auxiliary Heat

 

With KW of Auxiliary heat

 

Ambient

 

 

 

 

 

 

 

°F.

capacity

 

 

 

 

 

 

 

btuh

c.o.p.

4.8

9.6

14.4

 

19.2

65

51.54

4.44

67.92

84.30

100.68

 

117.07

60

48.79

4.28

65.17

81.55

97.94

 

114.32

55

45.92

4.11

62.30

78.68

95.07

 

111.45

50

42.93

3.92

59.31

75.69

92.07

 

108.46

45

39.73

3.70

56.11

72.49

88.88

 

105.26

40

36.90

3.50

53.28

69.66

86.05

 

102.43

35

34.03

3.30

50.41

66.79

83.18

 

99.56

30

34.27

3.26

50.65

67.03

83.41

 

99.79

25

31.63

3.08

48.01

64.39

80.77

 

97.15

20

29.12

2.90

45.50

61.89

78.27

 

94.65

15

26.48

2.70

42.86

59.25

75.63

 

92.01

10

23.76

2.48

40.14

56.52

72.91

 

89.29

5

21.07

2.25

37.45

53.83

70.21

 

86.59

0

18.37

2.01

34.75

51.13

67.52

 

83.90

-5

15.68

1.76

32.06

48.44

64.82

 

81.20

-10

12.84

1.48

29.22

45.61

61.99

 

78.37

Model: SSZ140481A* / CA*F4860*6A*+TXV / MBR2000**-1

Conditions: 1550 CFM Indoor Air @ 70°F DB

Outdoor

Basic Unit without

 

Capacity of Unit*

 

Auxiliary Heat

 

With KW of Auxiliary heat

 

Ambient

 

 

 

 

 

 

 

°F.

capacity

 

 

 

 

 

 

 

btuh

c.o.p.

4.8

9.6

14.4

 

19.2

65

57.82

4.25

74.20

90.59

106.97

 

123.35

60

54.74

4.10

71.12

87.50

103.89

 

120.27

55

51.52

3.94

67.90

84.28

100.67

 

117.05

50

48.16

3.76

64.54

80.93

97.31

 

113.69

45

44.57

3.55

60.96

77.34

93.72

 

110.10

40

41.40

3.36

57.78

74.16

90.55

 

106.93

35

38.18

3.17

54.56

70.94

87.33

 

103.71

30

36.62

2.94

53.00

69.38

85.76

 

102.15

25

33.80

2.77

50.18

66.56

82.94

 

99.32

20

31.12

2.61

47.50

63.89

80.27

 

96.65

15

28.30

2.43

44.68

61.06

77.45

 

93.83

10

25.39

2.24

41.77

58.16

74.54

 

90.92

5

22.51

2.03

38.89

55.28

71.66

 

88.04

0

19.63

1.82

36.01

52.40

68.78

 

85.16

-5

16.75

1.59

33.13

49.52

65.90

 

82.28

-10

13.72

1.34

30.11

46.49

62.87

 

79.25

Model: SSZ140601A* / CA*F4860*6A*+TXV / MBE2000**-1

Conditions: 1850 CFM Indoor Air @ 70°F DB

Outdoor

Basic Unit without

 

Capacity of Unit*

 

Auxiliary Heat

 

With KW of Auxiliary heat

 

Ambient

 

 

 

 

 

 

 

°F.

capacity

 

 

 

 

 

 

 

btuh

c.o.p.

4.8

9.6

14.4

 

19.2

65

71.65

4.34

88.03

104.41

120.80

 

137.18

60

67.83

4.19

84.21

100.59

116.98

 

133.36

55

63.84

4.03

80.22

96.60

112.99

 

129.37

50

59.68

3.85

76.06

92.44

108.83

 

125.21

45

55.23

3.64

71.62

88.00

104.38

 

120.76

40

51.30

3.45

67.68

84.06

100.45

 

116.83

35

47.31

3.26

63.69

80.07

96.46

 

112.84

30

47.86

3.17

64.24

80.63

97.01

 

113.39

25

44.17

2.99

60.56

76.94

93.32

 

109.70

20

40.68

2.83

57.06

73.44

89.83

 

106.21

15

36.99

2.63

53.37

69.76

86.14

 

102.52

10

33.19

2.43

49.57

65.95

82.34

 

98.72

5

29.42

2.21

45.81

62.19

78.57

 

94.95

0

25.66

1.98

42.04

58.42

74.81

 

91.19

-5

21.90

1.74

38.28

54.66

71.04

 

87.43

-10

17.94

1.46

34.32

50.70

67.09

 

83.47

*To obtain BTU capacity of unit with KW of auxiliary heat, multiply by 1000 (Example: 39.01 x 1000 = 39,010 BTU)

24

Page 24
Image 24