HEATING SPECIFICATIONS

HEATING SPECIFICATIONS

Model: SSZ140181A* / CA*F3131*6A*+TXV / MBR800**-1

Conditions: 600 CFM Indoor Air @ 70°F DB

Outdoor

Basic Unit without

 

Capacity of Unit*

 

Auxiliary Heat

 

With KW of Auxiliary heat

 

Ambient

 

 

 

 

 

 

 

°F.

capacity

 

 

 

 

 

 

 

btuh

c.o.p.

4.8

9.6

14.4

 

19.2

65

22.63

4.23

39.01

55.39

71.77

 

88.16

60

21.42

4.09

37.80

54.18

70.57

 

86.95

55

20.16

3.93

36.54

52.92

69.31

 

85.69

50

18.85

3.75

35.23

51.61

67.99

 

84.38

45

17.44

3.54

33.82

50.21

66.59

 

82.97

40

16.20

3.36

32.58

48.96

65.35

 

81.73

35

14.94

3.16

31.32

47.70

64.09

 

80.47

30

12.80

2.70

29.18

45.56

61.94

 

78.33

25

11.81

2.55

28.19

44.57

60.96

 

77.34

20

10.88

2.40

27.26

43.64

60.02

 

76.41

15

9.89

2.24

26.27

42.65

59.04

 

75.42

10

8.87

2.06

25.26

41.64

58.02

 

74.40

5

7.87

1.87

24.25

40.63

57.01

 

73.40

0

6.86

1.67

23.24

39.62

56.01

 

72.39

-5

5.85

1.47

22.24

38.62

55.00

 

71.38

-10

4.80

1.23

21.18

37.56

53.94

 

70.33

Model: SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1

Conditions: 850 CFM Indoor Air @ 70°F DB

Outdoor

Basic Unit without

 

Capacity of Unit*

 

Auxiliary Heat

 

With KW of Auxiliary heat

 

Ambient

 

 

 

 

 

 

 

°F.

capacity

 

 

 

 

 

 

 

btuh

c.o.p.

4.8

9.6

14.4

 

19.2

65

30.17

4.24

46.55

62.93

79.32

 

95.70

60

28.56

4.09

44.94

61.32

77.71

 

94.09

55

26.88

3.93

43.26

59.64

76.03

 

92.41

50

25.13

3.74

41.51

57.89

74.28

 

90.66

45

23.26

3.54

39.64

56.02

72.40

 

88.79

40

21.60

3.35

37.98

54.36

70.75

 

87.13

35

19.92

3.16

36.30

52.68

69.07

 

85.45

30

17.93

2.81

34.31

50.70

67.08

 

83.46

25

16.55

2.65

32.93

49.32

65.70

 

82.08

20

15.24

2.50

31.62

48.01

64.39

 

80.77

15

13.86

2.33

30.24

46.62

63.01

 

79.39

10

12.43

2.14

28.82

45.20

61.58

 

77.96

5

11.02

1.94

27.41

43.79

60.17

 

76.55

0

9.61

1.73

26.00

42.38

58.76

 

75.14

-5

8.20

1.52

24.59

40.97

57.35

 

73.73

-10

6.72

1.28

23.10

39.49

55.87

 

72.25

Model: SSZ140301A* / CA*F3642*6A*+TXV / MBR1600**-1

Conditions: 1050 CFM Indoor Air @ 70°F DB

Outdoor

Basic Unit without

 

Capacity of Unit*

 

Auxiliary Heat

 

With KW of Auxiliary heat

 

Ambient

 

 

 

 

 

 

 

°F.

capacity

 

 

 

 

 

 

 

btuh

c.o.p.

4.8

9.6

14.4

 

19.2

65

36.45

4.44

52.84

69.22

85.60

 

101.98

60

34.51

4.28

50.89

67.27

83.66

 

100.04

55

32.48

4.10

48.86

65.24

81.63

 

98.01

50

30.36

3.91

46.75

63.13

79.51

 

95.89

45

28.10

3.69

44.48

60.87

77.25

 

93.63

40

26.10

3.50

42.48

58.86

75.25

 

91.63

35

24.07

3.29

40.45

56.83

73.22

 

89.60

30

22.62

3.01

39.00

55.39

71.77

 

88.15

25

20.88

2.84

37.26

53.64

70.03

 

86.41

20

19.23

2.67

35.61

51.99

68.37

 

84.76

15

17.48

2.48

33.87

50.25

66.63

 

83.01

10

15.69

2.28

32.07

48.45

64.83

 

81.22

5

13.91

2.07

30.29

46.67

63.05

 

79.44

0

12.13

1.85

28.51

44.89

61.27

 

77.66

-5

10.35

1.62

26.73

43.11

59.50

 

75.88

-10

8.48

1.36

24.86

41.24

57.63

 

74.01

Model: SSZ140361A* / CA*F4860*6A*+TXV / MBR1600**-1

Conditions: 1050 CFM Indoor Air @ 70°F DB

Outdoor

Basic Unit without

 

Capacity of Unit*

 

Auxiliary Heat

 

With KW of Auxiliary heat

 

Ambient

 

 

 

 

 

 

 

°F.

capacity

 

 

 

 

 

 

 

btuh

c.o.p.

4.8

9.6

14.4

 

19.2

65

43.49

4.17

59.87

76.26

92.64

 

109.02

60

41.17

4.02

57.56

73.94

90.32

 

106.70

55

38.75

3.86

55.13

71.52

87.90

 

104.28

50

36.23

3.68

52.61

68.99

85.37

 

101.76

45

33.53

3.48

49.91

66.29

82.67

 

99.06

40

31.14

3.30

47.52

63.90

80.29

 

96.67

35

28.72

3.11

45.10

61.48

77.87

 

94.25

30

28.82

3.03

45.20

61.58

77.97

 

94.35

25

26.60

2.86

42.98

59.36

75.75

 

92.13

20

24.49

2.70

40.88

57.26

73.64

 

90.02

15

22.27

2.51

38.66

55.04

71.42

 

87.80

10

19.98

2.31

36.37

52.75

69.13

 

85.51

5

17.72

2.10

34.10

50.48

66.86

 

83.25

0

15.45

1.87

31.83

48.22

64.60

 

80.98

-5

13.18

1.64

29.57

45.95

62.33

 

78.71

-10

10.80

1.38

27.18

43.57

59.95

 

76.33

*To obtain BTU capacity of unit with KW of auxiliary heat, multiply by 1000 (Example: 39.01 x 1000 = 39,010 BTU)