1.Screw the bung adapter (M) into the bung hole of the drum. See FIG. 7.
2.For 246907 cut the extension tube (P) at a 45° angle to a length appropriate for the size of the drum. When installed, the bottom of the angle should be about 1” (25 mm) from the bottom of the drum. For 224640 and 225931 the down tube is sized for the container.
Installation
3.Tighten the bung adapter screw (T) to hold the pump in position.
4.Apply thread sealant to the male threads of the 3/8 npt swivel union (2d). Screw the union into the pump air inlet (D).
5.Apply thread sealant to the male threads of the 1/2 npt swivel union (2b). Screw the union into the pump fluid outlet (N).
6.Connect the 1/2 npt(mbe) fluid hose (2a) to the swivel union (2b).
7.Connect the 3/8 npt(mbe) air hose (2c) to the swivel union (2d).
| F |
|
D | N | 2b |
| ||
|
| |
2d |
| 2a |
|
|
2c
M
T
P
Model 225931
FIG. 7
12 | Installation and Operation |