1.Apply thread sealant to the male threads of the 3/8 npt swivel union (2d). Screw the union into the pump air inlet (D).
F
Installation
2.Apply thread sealant to the male threads of the 1/2 npt swivel union (2b). Screw the union into the pump fluid outlet (N).
3.Connect the 1/2 npt(mbe) fluid hose (2a) to the swivel union (2b).
4.Connect the 3/8 npt(mbe) air hose (2c) to the swivel union (2d).
2d
D N
2b
2a
2c
FIG. 3