Technical Data
30 Installation and Operation
Technical Data

Fire-Ball 225 (3:1)

Fluid to air ratio......................................................... 3:1
Cycles/gallon (cycles/liter)............................ 43.5 (11.4)
Fluid flow @80 cpm (gpm/lpm)....................... 1.84 (7.0)
Pumping distance guideline.......... up to 250 ft. (76.2 m)
Maximum fluid pressure........ 540 psi (3.7 MPa, 37 bar)
Air motor effective diameter.............. 2.25 in. (57.2 mm)
Air operating range............... 40-180 psi (0.28-1.2 MPa,
...................................................................... 2.8-12 bar)
Approx. air consumption and fluid flow @100 psi air and
80 cpm..... 8.5 scfm @2.1 gpm (.241 m3/min @7.9 lpm)
Dry suction lift (feet of water)......................................23
Wetted materials............steel, polyurethane, aluminum,
...............................................................buna-N, Rulon®
Air inlet port size......................................... 3/8 in. npt(f)
Fluid inlet port size ..................................... 1.5 in. npt(f)
Fluid outlet port size ................................... 1/2 in. npt(f)
Sound pressure (measured 1 meter from unit)...77.8dB
Sound pressure (ISO 9614-2) ............................85. 6dB

Fire-Ball 300 (5:1)

Fluid to air ratio......................................................... 5:1
Cycles/gallon (cycles/liter).............................. 28.4 (8.6)
Fluid flow @80 cpm (gpm/lpm)......................... 2.8 (9.3)
Pumping distance guideline........up to 500 ft. (152.5 m)
Maximum fluid pressure........ 900 psi (6.2 MPa, 62 bar)
Air motor effective diameter................ 3.0 in. (76.2 mm)
Air operating range............... 40-180 psi (0.28-1.2 MPa,
...................................................................... 2.8-12 bar)
Approx. air consumption and fluid flow @100 psi air and
80 cpm..... 8.5 scfm @2.1 gpm (.241 m3/min @7.9 lpm)
Dry suction lift (feet of water)......................................26
Wetted materials ........... steel, polyurethane, aluminum,
........................................................................... buna-N
Air inlet port size .........................................3/8 in. npt(f)
Fluid inlet port size...................................... 1.5 in. npt(f)
Fluid outlet port size.................................... 1/2 in. npt(f)
Sound pressure (measured 1 meter from unit)...77.8dB
Sound pressure (ISO 9614-2)............................. 85.6dB

Fire-Ball 425 (10:1)

Fluid to air ratio.............. .........................................10:1
Cycles/gallon (cycles/liter) ..............................19.6 (5.2)
Fluid flow @80 cpm (gpm/lpm)...... .................4.1 (15.4)
Pumping distance guideline........up to 750 ft. (228.6 m)
Maximum fluid pressure...1800 psi (12.4 MPa, 124 bar)
Air motor effective diameter............ 4.25 in. (107.9 mm)
Air operating range ...............40-180 psi (0.28-1.2 MPa,
......................................................................2.8-12 bar)
Approx. air consumption and fluid flow @100 psi air and
80 cpm.32.0 scfm @4.1 gpm (.555 m3/min @15.4 lpm)
Dry suction lift (feet of water) .....................................26
Wetted materials..steel, polyurethane, aluminum, nitrile
Air inlet port size .........................................1/2 in. npt(f)
Fluid inlet port size...................................... 1.5 in. npt(f)
Fluid outlet port size.................................... 3/4 in. npt(f)
Sound pressure (measured 1 meter from unit).80.85dB
Sound pressure (ISO 9614-2)........................... 94.62dB