Troubleshooting

Relieve the pressure before you check or repair the meter. Be sure all other valves and controls and the pump are operating properly.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 5.

Problem

Cause

Solution

 

 

 

Battery icon is displayed.

Battery is low.

Replace the battery. See Replacing

 

 

the Battery on page 16.

 

 

 

Battery icon is blinking, and

Battery is dead.

Replace the battery. See Replacing

bAtt is blinking.

 

the Battery on page 16.

 

 

 

Display does not activate.

Battery is defective or dead.

Replace the battery. See Replacing

 

 

the Battery on page 16.

 

Electronic control is malfunctioning.

Replace the electronic control

 

A dispense mode has not been

(clamshell).

 

 

 

selected.

Select a dispense mode by pressing

 

 

the Manual/Reset button or the

 

 

Auto/Reset button.

 

 

 

Slow or no fluid flow

Filter is clogged.

1. Relieve the pressure.

 

 

2. Clean or replace the filter. See

 

 

Replacing the Filter on page 16.

 

 

3. If the problem remains, contact

 

 

your Graco distributor for repair

 

 

or replacement.

 

Pump pressure is low.

Turn up pump pressure.

 

Shut-off valve is not fully open.

Fully open shut-off valve.

 

Foreign material is jammed in the

Contact your Graco distributor for

 

meter housing.

repair or replacement.

 

 

 

Displayed dispensed amount

Unit needs to be calibrated for the

Calibrate the meter for the fluid that is

is not accurate.

fluid that is being dispensed.

being dispensed. See Calibration

 

 

Factor on page 9.

 

 

 

 

 

continued

309377 13

Page 13
Image 13