11309377
Operation

Locking and Unlocking the Trigger

The trigger on this dispense valve has a locking mech-
anism. In Auto mode, the unit stops dispensing when
the entered amount has been dispensed. In Manual
mode, the trigger does not automatically unlock; you
must unlock it manually.
Tolock the trigger, press on the part of the trigger
that has the textured grip (see below) until you feel it
click into the locked position.
Tounlock the trigger, press on the smooth part of
the trigger (see below) until you feel it click out of the
locked position. When you release the trigger, fluid
flow stops.
Press here
to lock.
Press here
to unlock. 06227A

Checking Segments in the Display

When you press the Manual/Reset button or the
Auto/Reset button when the display is awake and in
the Manual or Auto dispense mode, the Segment
Check is displayed briefly. This display allows you to
check for burned out segments in the display. Press
the Manual/Reset or Auto/Reset button repeatedly to
get a good look at each segment in the display. The
Segment Check should show all of the segments
shown below.
LITERS
PTS
GAL
R-TOTAL
AUTO CAL
06044A
,, ,
!CAUTION
Toprevent overfills andspills
MaximumWorking Pressure 7 M Pa (70 bar, 1000 PSI)
DDonot obstruct the trigger
DDonot leave unattended
DDonot operate below 32_F(0_C)
DReadinstruction manual
QTS

Dispensing Fluid in ManualMode

1. Press the Manual/Reset button.
If the display was asleep, it wakes up and displays
the amount that was displayed before it fell asleep.
If the displaywas awake, and the meter is in the
Manual dispense mode, the meter beeps, and the
display clears to 0.00.
If the displaywas awake, and the unit is in the View-
ing Totalsmode or theAut o dispense mode, the meter
switches to the Manual dispense mode.
2. When the display is awake, you can dispense from
zero or from the displayed amount by doing one of
the following:
DPress the Manual/Reset button again to clear
the display to 0.00 if it is not already at 0.00.
Then go to step 3.
OR
DGo straight to step 3 to dispense from the
displayed amount.
3. Squeeze the trigger. Youmay lock it . SeeLock-
ing and Unlockingthe Trigger at left.
Fluid flows, and the amount displayed counts up from
zero or the previously dispensed amount.
4. Release/unlock the trigger when you have dis-
pensed the desired amount of fluid.
Fluid flow stops, and the amount you have dispensed
is displayed.
Youm ay press the Manual/Reset button again to reset
the displayed amount to zero.
NOTE: When the trigger is released, the automatic
nozzle prevents the fluid in the extension from running
out.