8 309377
Setup
Selecting DispensingOptions
This is the procedure for setting or changing the resettable tot al, units of measurement, calibration factor, auto
preset amount, and shut-off default amount:
1. If the display is asleep, wake it up by pressing the Manual/Reset or Aut o/Reset button.
2. Toenter the dispensing opt ions menus from any mode, press and hold the Manual/Reset and Aut o/Reset
buttons simultaneouslyfor four seconds.
The first menu is the Resettable Total menu, which is described in the first subsection below. You can advance
through the menus by pressing the Auto/Reset button. You will know which menu you are in, because a menu
indicator will be blinking in the display. The value that is displayed when you leave each menu and advance to
the next is the value that gets stored.
Resettable Total
In this menu, you can reset the resettable total to zer o
or leave it unchanged. The resettable total accumu-
lates until the next time it is manually reset.
1. If you have not already entered the dispensing
options menus, do steps 1 and 2 in Selecting
Dispensing Options above.
2. With R--TOTALblinking and the current resettable
total displayed, as shown below, do ONEof the
following two options:
DPress the Manual/Reset button.
The resettable total is set to zero, and 0GALor0
LITERS is displayed.
Youc an press the Manual/Reset button again to toggle
between zero and the previously displayed resettable
total. Tolock int he displayed value and advance to
the Units of Measurement menu, press the Auto/Reset
button.
OR
DPress the Auto/Reset button.
The currently displayed value is stored, and the display
advances to the Units of Measurement menu.
R-TOTAL
GAL
06044A
!CAUTION
Toprevent overfills andspills
MaximumWorking Pressure 7 M Pa (70 bar, 1000 PSI)
DDonot obstruct the trigger
DDonot leave unattended
DDonot operate below 32_F(0_C)
DReadinstruction manual
Units of Measurement
In this menu, you can set the units of measurement to
quarts, gallons, pints, or liters.
1. If you have not already entered the dispensing
options menus, do steps 1 and 2 in Selecting
Dispensing Options above.
2. Press the Auto/Reset button repeatedly until QTS,
GAL,LITERS,or PTS blink s to indicate that you
are in the Units-of Measurement menu.
3. With QTS,GAL,LITERS, or PTS blinking, as
shown below, do ONEof the following two options:
DPress the Manual/Reset button.
Each time you press the Manual/Reset button, the
display scrolls to the next unit of measurement. To
lock in the new unit of measurement and advance to
the Calibration Factor menu, press the Auto/Reset
button.
OR
DPress the Auto/Reset button.
The displayed unit of measurement is retained, and
the display advances to the Calibration Factor menu.
GAL
06044A
!CAUTION
Toprevent overfills andspills
MaximumWorking Pressure 7 M Pa (70 bar, 1000 PSI)
DDonot obstruct the tr igger
DDonot leave unattended
DDonot operate below 32_F(0_C)
DReadinstruction manual