Grounding Procedure (For Flammable Materials Only)
Grounding Procedure | Pressure Relief Procedure |
(For Flammable Materials Only)
This equipment must be grounded to reduce the risk of static sparking. Static sparking can cause fumes to ignite or explode. Grounding provides an escape wire for the electric current.
1.Position striper so that the tires are not on pave- ment.
2.Ground sprayer with grounding clamp. Grounding clamp must attach to grounded object (e.g. metal sign post).
ti3306a
This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing the equipment.
1.Perform Grounding Procedure if using flammable materials.
2.Set pump valve OFF. Turn engine OFF.
ti6740a
3.Turn pressure control to lowest setting. Trigger gun to relieve pressure.
ti3305a
ti3441a | PAINT |
4. Engage gun trigger safety. Turn prime valve down.
ti6473a
ti3324a
8 | 3A2090A Operation |