RESTRICTED USE ONLY | Fargo Electronics, Inc. |
Using the Verification radio buttons and Retries selection
Use this option to customize the Encoding verification settings.
Step Procedure
1Select the Auto Eject 1st Error option to instruct the Printer to verify that all magnetic data has been correctly encoded on each card. (Note: The Auto Eject option is the most direct means of dealing with misverified cards; however, it may be undesirable when dealing with Encoding errors. For this reason, a Manual Eject Each Error option is also provided.)
•Auto Eject 1st Error option: If the Auto Eject 1st Error option is selected, the Printer will automatically eject a card containing magnetic data that cannot be verified and will feed a new card into the Printer. (Note: Only the first misverified card would be automatically ejected.)
•Manual Eject Mode option: If a second consecutive card cannot be verified,
the Printer will signal an error and go into a Manual Eject Mode. (Note: If the loaded cards have the wrong type of Magnetic Stripe, the Printer will not automatically feed and eject the entire card supply.)
OR
Select the Manual Eject Each Error option so that the Printer will signal an error communicating the magnetic data could not be verified.
•Unverified Magnetic Data: When this occurs, press the Pause/Resume button to manually eject the misverified card and feed in a new card.
•Retries selection: Specify the number of times the Printer must retry its
verification pass. (Note: A range of 1 to 5 retries can be selected. This option is helpful since successful Magnetic Stripe verification can sometimes require more than a single pass.)
Persona C16 Card Printer Service Manual (Rev. 5.0) | 111 |