Replacing the Lower Ribbon Sensor Assembly — C16 (83012612)

Refer to Drawing 83012612

Estimated Repair Time: 15 minutes.

Steps

Procedures

 

 

1

 

 

Caution: Turn off the Printer and unplug the power cord from the

 

Printer.

 

 

2

Open the Upper Imaging Assembly.

 

 

3

Loosen the top two corner screws (130987) found just behind the top edge of

 

the Rear Cover.

 

 

4

Close the Upper Imaging Assembly.

 

 

5

Remove the screw (130987) by the Card Exit Ramp.

 

 

6

Remove the Rear Cover.

 

 

7

Remove the two screws (130971) that secure the Print Circuit Board to the two

 

Standoff screws (140047).

 

 

8

Remove the screws that hold the Main Board Brackets in place.

 

 

9

Use the thumb and index fingers of both hands to carefully pry the Print Circuit

 

Board from the Power Circuit Board.

 

 

10

Remove the screw (130971) that holds the Lower Ribbon Sensor Assembly to

 

the Rear Side Plate.

 

 

11

Disconnect the cable connector from J12, pins 1and 2 on the Print Circuit Board.

 

 

12

Remove the LED Board Assembly from the Bottom Sensor Bracket and the

 

Printer.

 

 