RESTRICTED USE ONLYFargo Electronics, Inc.

Reviewing the Printer Timing

Interval

Description

Minimum Value

 

 

 

Tdsu

Data setup time

0.5 \s

 

 

 

 

 

 

Tstr

Data strobe width

 

 

 

 

1 \s

 

 

 

 

 

Tack

 

 

 

 

 

Acknlg pulse width

 

 

 

 

 

3.75 \s

 

 

 

 

 

Tdh

Data hold time

0.5 \s

 

 

 

Tsb

 

 

 

 

 

Busy delay time from data

 

 

strobe

 

 

 

 

 

0.5 \s (max.)

 

 

 

 

 

Persona￿ C16 Card Printer Service Manual (Rev. 5.0)