FARGO electronic C16 service manual Replacing the Upper Ribbon Sensor Assembly, Refer to Drawing

Models: C16

1 259
Download 259 pages 54.74 Kb
Page 187
Image 187
Replacing the Upper Ribbon Sensor Assembly (83015111)

RESTRICTED USE ONLY

Fargo Electronics, Inc.

Replacing the Upper Ribbon Sensor Assembly (83015111)

Refer to Drawing 830119-XX

Estimated Repair Time: 20 minutes.

Steps

Procedure

 

 

1

 

 

Caution: Turn off the Printer and unplug the power cord from the

 

Printer.

 

 

2

Open the Upper Imaging Assembly.

 

 

3

Loosen the top two corner screws (130987) found just behind the top edge of the

 

Rear Cover.

 

 

4

Close the Upper Imaging Assembly.

 

 

5

Remove the screw (130987) by the Card Exit Ramp.

 

 

6

Remove the Rear Cover.

 

 

7

Open the Upper Imaging Assembly.

 

 

8

Remove the screws (130948) from the four corners of the top cover.

 

 

9

Close the Upper Imaging Assembly.

 

 

10

Lift the top cover from the Printer

 

 

11

Take the two screws (130990) from the Fan Guard (150312); lift the fan out of

 

the Printer.

 

 

12

Remove the two screws (130971) that secure the Shield Sensor (810303) to the

 

Sensor Mount Bracket (810221).

 

 

13

Take the Ribbon Sensor Assembly from the Printer.

 

 

Continued on the next page

Persona￿ C16 Card Printer Service Manual (Rev. 5.0)