Long Term (more than 30 days)/Winter Storage

Long Term (more than 30 days)/Winter Storage

SDo not store unit outside where it can be exposed to rain, dirt or adverse weather conditions.

SDo not expose pressure washer to freezing temperatures or allow water to freeze in pressure washer components, causing the pump to lock–up. If this happens let pump thaw naturally in WARM ENVI- RONMENT. DO NOT attempt to to speed up this process by pouring warm water on pump. This could cause further damage.

ENGINE:

1.Run engine until gas is gone or stabilize the fuel and run it through the fuel system and carburetor.

2.Drain water out of pressure washer hose.

3.Turn fuel system to OFF position.

Pump:

1.Attach one end of a 4 or 5–foot section of hose to pump inlet and other end in an antifreeze solution approx- imately 1–foot off the ground.

2.Pull pull–cord on engine until antifreeze comes out of pump outlet.

Storage Location:

1. Store pressure washer in garage, basement or other area where it is protected from freezing temperatures.