Installing and Changing Spray Tips

Spray tips have 4– or 5–digit numbers on them. The first two digits are the spray angle. Tip holding holes are provided on the chassis.

Spray Tip

Spray Pattern Fan Angle

 

Number

 

 

00XXX

0_ blaster (red)

 

 

 

15XXX

15_ (yellow)

 

 

 

 

25XXX

25_ (green)

 

 

 

40XXX

40_ (white)

 

 

 

Chemical

XX_ (black)

 

 

 

NOTE: The chemical injector tip is brass and has a large opening and a black plastic cap.

1.Perform Pressure Relief Procedure, page 7.

2.Point the gun and wand away from you and anyone else.

3. Without holding your hand over spray tip (A), pull back quick

 

coupler ring (B). Remove current tip. Install a different one.

B

Then push the ring back on.

 

A

 

CAUTION

To avoid blowing the o–ring out of the quick coupler due to the high pressure in the system, never operate pressure washer without a tip securely mounted in quick coupler.