Installation
Supplied Components
Refer to Fig. 2 for a typical installation of an airless system.
WARNING
A
The
The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient.
DThe red-handled bleed-type master air valve
(14)is required in your system to relieve air trapped between it and the air motor when the valve is closed (see the WARNING above). Be sure the bleed valve is easily accessible from the pump, and is located downstream from the air regulator.
DThe air regulator (8) controls pump speed and outlet pressure by adjusting the air pressure to the pump. Locate the regulator close to the pump, but upstream from the
DThe air manifold (15) has a swivel air inlet. It mounts to the cart, and provides ports for connect- ing lines to
DThe fluid filter (4) includes a 60 mesh (250 mi- cron) stainless steel element to filter particles from the fluid as it leaves the pump.
DThe fluid drain valve (7) is required in your sys- tem to relieve fluid pressure in the hose and gun (see the WARNING above).
DThe suction hose (24) and tube (25) allow the pump to draw fluid from a 200 liter (55 gallon) drum.
System Accessories
Air and Fluid Hoses
Be sure all air hoses (A) and fluid hoses (G) are prop- erly sized and
1.Connect one end of the fluid line (G) to the filter outlet swivel. Connect a fluid hose to each gun (H). Install a fluid shutoff valve (J) at each gun drop. Do not install the spray tip in the gun yet.
2.Close the
Air Line Accessories
1.Install an air line filter (B) in the main air line, to remove harmful dirt and moisture from the com- pressed air supply.
2.Install a second bleed valve (C) in the main air line, to isolate the accessories for servicing.
3.Install a drain valve (D) at the bottom of each air line drop, to drain off moisture.
4.To provide automatic lubrication of the air motor, install an air line lubricator (E) downstream from the
5.Install a pump runaway valve (F). The runaway valve will automatically shut off the air to the pump if the pump starts running too fast. A pump that runs too fast can be seriously damaged.
6 307932