Installation
Models 245185 and 245186 (for Heated Temperature Spray Applications)
1.Be sure the wall is strong enough to support the weight of the pump and accessories, heaters, hoses, fluid, and stress caused during operation.
4.Use M8 or 5/16 in. bolts of the appropriate length and lockwashers (not supplied) to fasten the heater brackets to the wall.
5.Bring the hose (31a) from the inlet elbow (32a) of the lower heater (44a) and connect it securely to the swivel (50) coming from the pump outlet. See Fig. 4.
2.Mount the pump wall bracket (2) 5 ft (1.5 m) above the floor. Refer to the Mounting Hole Layout on page 20.
3.Locate the holes for the heater wall brackets (26*) exactly as indicated on page 20. Use the heater wall brackets as templates to mark the wall.
NOTE: Refer to the Mounting Hole Layout on page
20.Note that one set of mounting holes is above and slightly to the left of the other. Install the heater (44) with the fluid filter (4) attached in that set of holes. Install the heater without the fluid filter (4) in the lower set of holes.
6.Route the hose (31b) from the inlet elbow (32b) of the upper heater (44b), behind the lower heater (44a), and connect it securely to the swivel (34a) at the outlet of the lower heater.
7.Bring the fluid supply hose (31) from the swivel (34b) at the fluid filter (4) outlet and connect it to the main fluid supply line to the guns.
8.Bring the fluid return hose (37) from the
9.Connect the air and fluid hoses and the spray gun as explained on page 6.
1 Connect supply hose (31) to the main fluid supply line to the guns.
2 | Connect return hose (37) to the main fluid return line. | 44b |
|
32b
32a
237
50
40
31 1
34b
4
34a
31b
44a
31a
| 04419D | |
Fig. 4 | ||
|
307932 9