Warnings
Warnings
The following warnings are for the setup, use, maintenance, and repair of this equipment. The exclamation point sym- bol alerts you to a general warning and the hazard symbols refer to
WARNING
GROUNDING
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.
•Improper installation of the grounding plug is able to result in a risk of electric shock.
•When repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal.
•The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.
•Check with a qualified electrician or serviceman when the grounding instructions are not completely understood, or when in doubt as to whether the product is properly grounded.
•Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qualified electrician.
•This product is for use on a nominal 120V circuit and has a grounding plug similar to the plug illustrated in the figure below.
•Only connect the product to an outlet having the same configuration as the plug.
•Do not use an adapter with this product.
Extension Cords:
•Use only a
•Make sure your extension cord is not damaged. When using an extension cord, be sure to use a cord heavy enough to carry the current that your sprayer draws. See chart for appropriate sizes and lengths:
Extension Cord Gauge | Extension Cord Length |
(AWG Minimum) | (Maximum) |
|
|
18 | 50 ft (15 m) |
|
|
16 | 100 ft (30 m) |
|
|
14 | 200 ft (60m) |
|
|
•An undersized extension cord will result in a drop in line voltage and loss of power, overheating, and possible damage to equipment.
3A0159E | 3 |