Troubleshooting

 

 

 

TYPE OF PROBLEM

WHAT TO CHECK

HOW TO CHECK

 

 

 

Drywall feed pump does not

Control is commanding motor to

1. Remove pump pin and try to run unit. If motor runs,

run at all

run but motor shaft does not

check for locked or frozen pump or drive train. If unit

 

rotate. Possibly locked rotor con-

does not run, continue to step 2.

Digital display shows E=05

dition, an open connection exists

 

 

2. Turn unit OFF and disconnect power to drywall feed

 

between motor and control, there

 

pump.

 

is a problem with motor or control

 

 

 

board.

3. Disconnect motor connector(s) from control board

 

 

Control board status light

 

leads. Check that motor connector and control board

blinks 5 times repeatedly

 

connectors are clean and secure.

 

 

4. Turn unit OFF and spin motor fan 1/2 turn. Restart

 

 

drywall feed pump. If unit runs, replace control

 

 

board. If unit does not run, continue to step 5.

 

 

5. Perform Spin Test: Test at large 4-pin motor field

 

 

connector. Disconnect fluid pump from unit. Test

 

 

motor by placing a jumper across pins 1 & 2. Rotate

 

 

motor fan at about 2 revolutions per second. A cogging

 

 

resistance to motion should be felt at the fan.

 

 

The motor should be replaced if no resistance is felt.

 

 

Repeat for pin combinations 1 & 3 and 2 & 3. Pin 4

 

 

(the green wire) is not used in this test. If all spin test

 

 

is positive, continue to step 6.

 

 

Green Blue Red Black

STEP 1:

Green Blue Red Black

STEP 2:

Green Blue Red Black

STEP 3:

3A0245B

21