Internal Air Valve-Operated Pumps Only

Troubleshooting

Internal Air Valve-Operated Pumps Only

PROBLEM

CAUSE

SOLUTION

 

 

 

The pump will not cycle, or it cycles

The air valve is stuck or dirty.

Disassemble and clean or repair the

once and stops.

 

air valve. See page 12.

 

 

Use filtered air.

 

Not enough air pressure supplied.

Increase air pressure supply. Do not

 

 

exceed maximum input pressure.

 

 

 

Remote Solenoid-Operated Pumps Only

PROBLEM

CAUSE

SOLUTION

The pump will not prime or loses prime.

The cycle rate is too low.

Increase cycle rate to 60 cpm.

The check valves (20) are not

Inspect the check valves, and

sealing.

replace them if worn or damaged.

 

See page 14.

Fluid manifold not mounted with OUT

Re-mount fluid manifold so OUT

port up.

port is up.

 

 

The pump leaks air or does not

Air is supplied to Port A and Port B

Replace both diaphragms (30).

operate.

at the same time.

See page 13.

 

 

Check your installation. See

 

 

page 7.

 

Solenoid exhaust is plugged.

Ensure that exhaust (G on page 7)

 

 

is free of obstructions.

 

 

 