Air Exhaust Ventilation

Installation

Air Exhaust Ventilation

TOXIC FLUID HAZARD WARNING

TOXIC FLUID HAZARD

Read the USING HAZARDOUS FLUIDS and FIRE AND EXPLOSION HAZARD sections on page 3 before you operate this pump.

Be sure the system is properly ventilated for your type of installation. You must vent the exhaust to a safe place, away from people, animals or food handling areas when pumping flammable or hazardous fluids.

If the diaphragm ruptures, the fluid being pumped is exhausted with the air. Place a container at the end of the air exhaust line to catch fluid in case the diaphragm ruptures, and disconnect the pump.

Mountings

Mountings CAUTION

The pump exhaust air may contain contaminants. If needed, ventilate to a remote area to reduce possible fluid contamination. See Air Exhaust Ventilation on page 5.

DMounting Bracket:

The pump is shipped with a 90 degree mounting bracket (60). Mount the pump to the bracket using the four screws (61) provided. Secure the opposite portion of the mounting bracket to a horizontal surface. The mounting bracket must be used for proper pump performance.

.

ti10662a

Fig. 2

DBe sure the mounting can support the weight of the pump, hoses, and accessories, as well as the stress caused during operation.

DFor all mountings, be sure the pump is secured with screws and nuts.

DMounting Bracket: WARNING

To reduce the risk of serious injury, splashing in the eyes or on the skin, and toxic fluid spills, never move or lift a pump under pressure. If dropped, the fluid section may rupture. Always follow the Pressure Relief Procedure on page 8 before you move or lift the pump.

308652 5