Installation
Air Lines
WARNING
Bleed-Type Master Air Valve and Fluid Drain Valve
A
The
The fluid drain valve reduces the risk of serious bodily injury, including splashing in the eyes or on the skin, or contamination from hazardous fluids. Install the fluid drain valve close to the pump’s fluid outlet to relieve pressure in the hose if the hose becomes plugged.
1.Mount the air line accessories on the wall or on a bracket. Be sure the air line supplying the acces- sories is grounded.
a.The pump speed can be controlled in one of two ways: To control it on the air side, install an air regulator. To control it on the fluid side, install a fluid valve near the outlet.
b.Install a
c.The air line filter removes harmful dirt and moisture from the compressed air supply.
2.Install a flexible air hose between the accessories and the pump air inlet. Screw the air line fitting into the air inlet.
3.Do not restrict the exhaust port. Excessive ex- haust restriction can cause erratic pump operation.
Fluid Lines
Fig. 3. On each end of the fluid manifold are a fluid IN port and a fluid OUT port. NOTE: Make sure the fluid OUT port on the fluid manifold is mounted up. This will assure proper pump priming.
| ti10661a | 06179A | |
Fig. 3 | |||
| |||
|
|
Typical Installation
The installations shown in Fig. 4 are only a guide to help select and install a pump; they are not actual system designs.
Typical installation includes (not supplied by Graco):
DFor solenoid operation: a
DPLC or timer. Consult your local industrial controls distributor.
CAUTION
For solenoid operation, the pump must exhaust through the solenoid. Failure to exhaust through solenoid could cause the diaphragms to fail.
6 308652