Troubleshooting

Problem

Cause

 

Solution

 

 

 

 

 

 

 

 

Flow rate too low.

Inadequate air supply.

 

Use larger CFM compressor.

 

 

 

 

 

 

Air pressure to pumps too low.

 

Increase pressure.

 

 

 

 

 

 

 

Fluid A or B filters plugged.

 

Clean filters.

 

 

 

 

 

 

Spray tip too small.

 

Relieve pressure. Install larger tip. Follow

 

 

 

gun manual instructions.

 

 

 

 

 

Mixer or hoses partially plugged or too

Inspect parts for cured material. Clean or

 

restrictive.

 

replace, or use larger hoses and mixer.

 

 

 

 

 

Insufficient dispense valve travel.

 

Increase travel. See 310655.

 

 

 

 

 

Shutoff valves are not fully open.

 

Ensure that shutoff valves are fully open

 

 

 

and sampling valves are closed.

 

 

 

 

 

Pump stops after 12 cycles.

Knob is set to Run pump A

or B

Turn knob to spray

if spraying mate-

rial.

 

 

 

 

 

 

independently.

 

 

 

 

 

 

 

 

Pump cycle rate slows and eventually

Icing at pump air manifold.

 

See Icing, page 9.

 

stops.

 

 

 

 

 

 

 

 

 