Maintenance

Preventive Maintenance

Schedule

Establish a preventive maintenance schedule, based on the pump’s repair history.

Mix Manifold

See mix manifold manual 310654.

Maintenance

Pump Test/Meter Calibration

See ProMix Easy Operation manual. If pumps/meters fail test, see Troubleshooting, page 10.

Wet Cup

Check pump and dispense valve wet-cups daily. Keep filled with Graco Throat Seal Liquid (TSL), Part No. 206995.

Dispense Valve

Storage

 

See dispense valve manual 310655.

Before storing the pump, always flush it, see ProMix Easy Operation manual. Relieve the pressure, page 7.

Pump

See applicable pump manual 310671, 310672, or 310662.

Turbine Alternator

Replace bearings every 2000 hours. See page 19.

Icing

If you experience icing at the pump air manifold:

Reduce pump input air pressure below 80 psi (0.56 MPa, 5.6 bar), if required spray pressure allows.

Reduce moisture in compressed air supply, or use heated air.

Air Filters

If icing persists, see table below.

Check daily. Drain and clean as necessary. See page 15.

Problem

Solution

 

 

 

 

Pump slows on both up

Turn D port bleed screw 60° (1/6 turn) counter-

 

and down stroke.

clockwise, to bleed 1 cfm air to melt ice.

 

 

 

 

Pump slows on down

Turn D port bleed screw 60° (1/6 turn) counter-

U

stroke.

clockwise, to bleed 1 cfm air to melt ice. If icing

D

 

 

continues, turn screw to 90° (1/4 turn) to increase

 

 

air flow to 2 cfm. If necessary, increase air flow to

 

 

3 cfm by turning screw to 270° (3/4 turn). Do not

 

 

exceed 3 cfm (3/4 turn maximum).

 

 

 

 

Pump slows on up stroke.

Turn U port bleed screw 90° (1/4 turn) counter-

 

 

clockwise, to bleed 1 cfm air to melt ice. If icing

 

 

continues, turn screw to 120° (1/3 turn) to

 

 

increase air flow to 2 cfm. If necessary, increase

 

 

air flow to 3 cfm by turning screw to 180° (1/2

TI5294a

 

turn). Do not exceed 3 cfm (1/2 turn maximum).

 

 

 

 

 