Graco 309909H Dispense Valve/Mix Manifold Assembly, Follow Pressure Relief Procedure

Models: 309909H

1 56
Download 56 pages 4.55 Kb
Page 21
Image 21

Dispense Valve/Mix Manifold Assembly

WARNING

Read warnings, page 5.

See the Parts drawing for your model.

1.Follow Pressure Relief Procedure, page 7.

2.Label all air and fluid lines, and disconnect from fit- tings on manifold assembly.

3.Remove fasteners.

4.Remove mix manifold (2).

5.To repair mix manifold, see manual 310654. To repair dispense valves, see manual 310655.

6.Reassemble.

Repair

Pump Assembly

WARNING

Read warnings, page 5.

See the Parts drawing for your model.

1.Follow Pressure Relief Procedure, page 7.

2.Remove side plates (21).

3.Remove wire harnesses from sensor and solenoids. Refer to Electrical Schematic, page 22.

4.Disconnect fluid inlet and outlet lines from pump lower. Disconnect air supply from pump.

5.Label all tubing and disconnect from fittings on pump assembly.

6.Remove mounting hardware and slide pump out of frame.

7.Repair as instructed in pump manuals 310671, 310672, or 310662.

8.Reassemble.