Graco 312359J Totalizers and Job Number, Clear Batch Totalizer, Maintenance 1 Screen

Models: 312359J

1 86
Download 86 pages 27.47 Kb
Page 74
Image 74

Appendix A

Totalizers and Job Number

View the grand and batch totals for each pump and both pumps combined. The units of measurement are dis- played on the bottom of the screen and displayed in the units of measurement selected during setup.

Grand total is the amount of material the system has dispensed during its lifetime. Batch total is the amount of material dispensed since the last user reset.

A job number can be entered to identify the batch total.

Clear Batch Totalizer

To clear the batch totalizer values for A, B, and A+B,

press to set all values to zero.

Maintenance 1 Screen

View setpoints for the amount of material that needs to move through both pumps and dosing valves that will result in a maintenance warning.

Maintenance 2 Screen

View number of days between changing the main incoming air filter before a reminder advisory is issued.

Icon Function

Displays batch total and grand total for pump A. The grand total is displayed at the top, and the batch total is displayed at the bottom.

Displays batch total and grand total for pump B. The grand total is displayed at the top, and the batch total is displayed at the bottom.

Displays batch total and grand total for both pumps combined. The grand total is displayed at the top, and the batch total is displayed at the bottom.

Displays job number for each spray period.

Change Job Number

1.Press to highlight the first digit. Press

and to change the number and and

to move to the next digit. Press to

save the number or to cancel.

Reset Maintenance Counter

1.Press and to scroll through and select the maintenance field to reset.

2.Press to reset the maintenance counter to zero.

74

312359J

Page 74
Image 74
Graco 312359J Totalizers and Job Number, Clear Batch Totalizer, Maintenance 1 Screen, Maintenance 2 Screen