Setup
8.Make certain ON/OFF switch is OFF.
ti24586a |
9.Plug power supply cord into a properly grounded electrical outlet.
ti24651a |
10. Turn prime valve down.
ti24608a |
334530A |
11.Place fluid intake with drain tube in grounded metal pail partially filled with flushing fluid. See Grounding, page 12.
NOTE: New sprayers are shipped with storage fluid that must be flushed out
with mineral spirits prior to using the
sprayer.
Check flushing fluid for compatibility with material that is to be sprayed. A secondary flush with a compatible fluid may be necessary. Water for latex paint or mineral spirits for
ti24640a |
12.Turn pressure control to OFF.
13.Turn ON/OFF switch to ON position.
14.Turn prime valve horizontal. Disengage trigger lock.
15.Turn pressure control to Prime/Slow.
16.Hold a metal part of the gun firmly to a grounded metal pail. Trigger gun and flush for one minute.
17.Turn ON/OFF switch to OFF position.
18.Engage trigger lock.
19.After flushing storage fluid out of the sprayer empty pail. Replace fluid intake with drain tube in grounded metal pail partially filled with flushing fluid. Use water to flush
20.Turn ON/OFF switch to ON position.
21.Turn prime valve horizontal. Disengage trigger lock.
17