Pressure Relief Procedure

Pressure Relief Procedure

Follow Flush Mixed Material, page 26 when you stop spraying or dispensing; and before cleaning, checking, servicing, or transporting equipment.

Relieve A and B Fluid Pressure

1. Engage the trigger lock.

TI1949a

2. Close the main air shutoff valve (CA).

CA

r_571100_3A0420A_11a-1

3.Shut off heaters, if used.

4.Shut off feed pumps, if used.

5.Remove the spray tip and clean.

6.Disengage the trigger lock.

TI1950a

TI1953a

 

7.Hold a metal part of the gun firmly to a grounded metal pail. Trigger the gun to relieve pressure.

8.Engage the trigger lock.

9.Close the dual shutoff handle (AE) and open the cir- culation handle (AC).

AC

AE

r_571101_3A0420A_9a-2

10.Always flush the mix hose after relieving A and B fluid pressure through the mix manifold. See Flush Mixed Material, page 26.

11.Shutoff the solvent supply pump and repeat steps 6-8 to relieve solvent pressure.

If the mixed material has already been flushed, but pressure remains on the A and B pumps, pressure can be relieved back to the hoppers (J).

a.Close the main air shutoff valve (CA).

b.Open the circulation handle (AC).

NOTE: For longer valve life in abrasive fluids, it is advisable to relieve high pressure out through the gun when possible.

12.If you suspect the spray tip or hose is clogged or that pressure has not been fully relieved after follow- ing the steps above, very slowly loosen tip guard retaining nut or hose end coupling to relieve pres- sure gradually, then loosen completely. Clear hose or tip obstruction.

13.If static mixer, whip hose, and gun cannot be flushed because of mixed and cured material, very slowly loosen static mixer tube from mix manifold outlet to relieve pressure gradually, then loosen completely. Replace or clean clogged components.

20

3A0420H

Page 20
Image 20
Graco XP70 important safety instructions Pressure Relief Procedure, Relieve a and B Fluid Pressure